Quickie Tango Скачать руководство пользователя страница 23

Quickie Tango

 

  

23

6.6 fixed seat tilt:

The seat can be tilted and set manually within a range of 

0° to 9° (Fig.6.4).

Undo the 2 studs.

• 

Move the seat to the desired tilt angle.

• 

Replace and tighten the 2 studs.

• 

6.7 manual seat tilt:

The manual seat tilt option allows tilt up to 25

°

, (Fig.6.5).

To operate the tilt;

Squeeze  the  tilt  actuator  lever  located  on  the  back 

• 

brace.

Use the push handles to move the seat to the desired 

• 

tilt angle.

Let the lever go.

• 

The seat tilt locks in place automatically. 

• 

fig.6.4

tIlt 

adjuster 

studs

6.8 powered seat tilt:

The seat can tilt up to 25 degrees by operating it through 

your control system or the Quickie Direct Actuator 

Control.

cautIon! 

Operating  the  powered  tilt  greater  than  9  degrees  from 

its  lowest  position  will  bring  the  chair  into  ‘creep  mode’, 

allowing slow speed driving only. 

To operate the powered tilt:

Push the mode button to select actuator mode.

Operate  the  joystick  left  or  right  to  select  the  actuator 

required (actuator 1 or actuator 2). Selection is indicated 

via the lighting of the orange LED adjacent to the desired 

actuator number.

Operate the joystick in the forward or rearward direction to 

move the tilt forward or backward.

Release the joystick when the desired angle is reached.

To return to drive mode, press the actuator button again.

Once the seat is fully tilted or in its lowest position do not 

hold  the  joystick  in  its  operat ing  position  as  this  could 

damage the actuator.

fig.6.5

seat tIlt 

actuator 

lever

Содержание Tango

Страница 1: ...Instructions for Use Quickie Tango Powered Wheelchair 034202 UK...

Страница 2: ...al com or alternatively is available on request in large text For further information on the full specification and options and accessories please refer to the order form All information is subject to...

Страница 3: ...it can be used by those who cannot walk or have limited mobility e g because of Paralysis Loss of extremity leg amputation Extremity defect deformity Joint contractures joint injuries Strokes and brai...

Страница 4: ...e of adjustments the Quickie Tango is a perfect choice for easy service refurbishment and recycle requirements As a part of our ongoing product improvement initiative Sunrise Medical reserves the righ...

Страница 5: ...0 12 3 Medium to long term storage 40 13 0 Disposal 41 14 0 Specifications 41 15 0 Guarantee 42 16 0 Service History 42 17 0 Performance checks 43 1 0 Your Wheelchair 7 2 0 How to use this manual 7 2...

Страница 6: ......

Страница 7: ...Sunrise Business Park High Street Wollaston West Midlands DY8 4PS England Phone 44 0 1384 44 66 88 Fax 44 0 1384 44 66 99 2 0 How to use this manual 2 1 Introduction Please keep a note of your local...

Страница 8: ...rect result of a The wheelchair or part not having been maintained or serviced in accordance with the manufacturer s recommendations as stated in the Owner s Manual and or Service Manual Or failing to...

Страница 9: ...and for conformance to strict standard requirements Changing the fitted position of the module can reduce the stability of the product therefore do not change this setting Battery Label Warning Instr...

Страница 10: ...l For further information please consult your Sunrise Medical authorised dealer DANGER 4 3 Preliminary checks You should not try to manoeuvre at full speed If you have to make a sudden turn slow down...

Страница 11: ...sition and secured by the wheelchair tie down and occupant restraint straps WTORS tie downs meeting the requirements of ISO 10542 or SAE J2249 in accordance with the WTORS manufacturers instructions F...

Страница 12: ...ig 4 4 The upper torso restraint belt should be mounted to the vehicle B pillar failure to do so will increase the risk of serious abdominal injuries to the user DANGER A head restraint suitable for t...

Страница 13: ...consistent with user comfort Restraint belt webbing must not be twisted when in use Restraints should be mounted to the vehicle B pillar and should not be held away from the body by wheelchair compon...

Страница 14: ...turned off The operation of cordless mobile telephones and cell phones including hands free devices is permitted but if abnormal operation of the wheelchair is encountered then the chair must be brou...

Страница 15: ...possible there may be other traffic WARNING 4 16 Adverse conditions Please be aware that when driving your wheelchair in adverse conditions e g on wet grass mud ice snow or other slippery surfaces you...

Страница 16: ...ou should start slowly On a RWD chair if necessary lean forward to prevent the tendency for the front wheels to lift WARNING 4 22 Gradients descents On descents it is important not to let the wheelcha...

Страница 17: ...t an angle of approximately 45 and when correctly adjusted should not allow user to slip down in the seat Fig 4 18 To fasten buckle Firmly push the male buckle into female buckle Fig 4 19 To release b...

Страница 18: ...n ask your healthcare professional wheelchair dealer carer or attendant for assistance WARNINGS The rider plus item should never exceed a total weight of 125 kg Before you use the chair carefully chec...

Страница 19: ...5 0 Fig 5 1 5 3 Anti tip wheels Fig 5 3 These are mounted when the wheelchair leaves the factory The anti tip wheel tube is welded to the motor retaining plate of the wheelchair frame Note Anti tips...

Страница 20: ...proceed as follows WARNING All wheels are safety critical items If you are unsure about performing these tasks please contact your approved Sunrise Medical dealer Front castor wheel Fig 5 6 Use a 6 mm...

Страница 21: ...interfering with the mechanisms of the chair Ensure that the crutch does not protrude from the chair Do not attempt to remove the crutch whilst the chair is in motion Always come to a complete stop a...

Страница 22: ...back 3 to 12 Fig 6 1 The backrest can be adjusted in 3 increments by removing the two star knobs To reposition choose the required back angle insert the two star knobs again and tighten 6 4 Manual Rec...

Страница 23: ...Direct Actuator Control CAUTION Operating the powered tilt greater than 9 degrees from its lowest position will bring the chair into creep mode allowing slow speed driving only To operate the powered...

Страница 24: ...If your chair has a powered seat tilt powered recline or manual recline back we strongly recommend that you bring the backrest into an upright position and set the seat tilt to the level position If...

Страница 25: ...rb climber or castor makes contact with the kerb step the wheelchair should be moving slowly Small kerbs can be climbed from a standstill Apply sufficient power to the motors to lift the front of the...

Страница 26: ...low To lock the wheelchair While the control system is switched on depress and hold the On Off button After 1 second the control system will beep Now release the On Off button Deflect the joystick for...

Страница 27: ...indicates if the speed of the wheelchair is being limited or if the control system is locked 7 6 The horn button The horn will sound while this button is depressed 7 7 Speed Profile decrease button Th...

Страница 28: ...perate this button the associated LED will flash at the same rate The left and right turn indicator LEDs will also flash If the LED flashes rapidly either a total short circuit a single lamp open circ...

Страница 29: ...ich joystick has control If the red wheelchair light is on the wheelchair occupants joystick has control If the green attendant light is on the dual attendant systems joystick has control The button i...

Страница 30: ...profile s needs adjustments to make it more convenient for the attendant and or the person sitting in the wheelchair please contact your Sunrise Service agent for adaptation If the direction of moveme...

Страница 31: ...can t find the problem try the self help guide on the next page Switch on the control system again and try to drive the wheelchair If the safety circuits operate again switch off and do not try to us...

Страница 32: ...r has a bad connection Check the connections to the left hand motor The left hand motor has a short circuit to a battery connection Contact your Sunrise Medical authorised dealer The right hand motor...

Страница 33: ...sed dealer as soon as possible who will carry out a full diagnostic to determine the cause of the original the fault WARNING Do not attempt to change the fuses yourself Do not attempt to by pass the f...

Страница 34: ...34 Quickie Tango Fig 9 2 Fig 9 4 Fig 9 6 Fig 9 8 Fig 9 3 Fig 9 5 Fig 9 7 Fig 9 9 Side clips Inner clips...

Страница 35: ...llowed this may result in lower than expected performance from your mobility vehicle 9 7 Maintenance free battery care plan Only use an approved Sunrise Medical charger compatible with the vehicle to...

Страница 36: ...ith the same type and size of fuse as specified Fitting of different fuses can result in damage to the charger or failure of the charger to operate properly If your charger has been specified for use...

Страница 37: ...ature is very hot or very cold Incorrect tyre pressures in one or more tyres Lots of start stop driving Also thick pile carpets within the home can affect range Use of additional power consumption opt...

Страница 38: ...y forwards 45mm Armrest retainer forward biased and armpad fixed in the fully backwards position 47 5mm Armrest retainer rearward biased and armpad fixed fully forwards 50mm Armrest retainer rearward...

Страница 39: ...wanted movement of your wheelchair Keep your fingers and clothing etc clear while operating the swing away mechanism Be aware that the width of your chair has increased if the swing away arm is out an...

Страница 40: ...nts The wheelchair may be transported by road rail sea or air and the batteries conform to IATA regulations CAUTION Before you travel please contact the appropriate carrier The travel operator will be...

Страница 41: ...ovable part Static stability downhill 20 3 tilt 3 recline Static stability uphill 14 3 tilt 3 recline Static stability sideways 18 3 tilt 3 recline Energy consumption max range 25km 6kph motor 100kg u...

Страница 42: ...exceeded if the product is carefully used and properly maintained The life expectancy can also be considerably reduced by extreme or incorrect usage The fact that we estimate a life expectancy for thi...

Страница 43: ...al for inside use low seat height compact dimensions as well as outside use lights 40Ah 50Ah batteries etc Its high level of flexibility due to the number of possible adjustments and the modular platf...

Страница 44: ...unrisemedical com Sunrise Medical Srl Via Riva 20 Montale 29100 Piacenza PC Italy Tel 39 0523 573111 Fax 39 0523 570060 www sunrisemedical com Sunrise Medical A G L ckhalde 14 3074 Muri bei Bern Switz...

Отзывы: