MAINTENANCE
The battery charger does not need any maintenance. To ensure optimum performance from the equipment, once a
year check the cables and the electrical connections.
TECHNICAL DATA
(1)
Maximum rated value at normal use or in short circuit.
(2)
With battery charger not supplied by the AC network.
(3)
At 50% of the output current on resistive load.
(4)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed the maxi-
mum nominal value of the equipment.
(5)
With supply voltage equal to 230 Vac and output current equal to the maximum nominal value.
(6)
With supply voltage equal to 120 Vac and output current equal to the maximum nominal value.
(7)
Protection may be inefficient in some operative conditions.
MODELS
SBC 140 NRG FR
SBC 250 NRG FR
SBC 300 NRG FR
SBC 365 NRG FR
OUTPUT CHARACTERISTICS
Maximum output current
(1)
12 A
25 A
30 A
15 A
Charge absorption voltage
14,1 Vdc OL open - 14,4 Vdc SL / gel / AGM
28,2 Vdc OL, 28,8 Vdc SL/gel/AGM
Charge float voltage
13,4 Vdc OL open - 13,8 Vdc SL / gel - 13,6 Vdc AGM
26,8 Vdc OL, 27,6 Vdc SL/gel, 27,2 Vdc AGM
DC absorption from the batteries
(2)
< 3,5 mA
Residual ripple
(3)
< 100 mV RMS
Charging characteristics
Automatic in three stages IUoU
Number of outputs
(4)
2
3
INPUT CHARACTERISTICS
Supply voltage
264÷83 Vac, with power reduction under 108 Vac
Frequency
45÷66 Hz
Maximum absorption (230/240 Vac)
(5)
0,9 A
1,8 A
2,1 A
2,1 A
Maximum absorption (120 Vac)
(6)
1,7 A
3,4 A
4,1 A
4,0 A
Power factor (cos
ϕ
)
(5)
1,00
Efficiency
(5)
≥
81%
PROTECTION
Reverse polarity
(7)
Yes, through fuse
Overload
Yes
Output short circuit
Yes
Overvoltage in output
Yes
Overheating
Yes
AMBIENT CHARACTERISTICS
Operating temperature
-15 ÷ +70 °C, with linear power reduction over +45 °C
Noisiness (acoustic)
< 43 dbA @ 1 m
< 47 dbA @ 1 m
Humidity
Max. 95% RV without condensation
CASE
Dimensions (WxHxD)
114 x 187 x 71 mm
114 x 252 x 71 mm
Weight
1,1 kg
1,6 kg
GENERAL
Safety standard
EN 60335-2-29
EMC Standard