SETTING THE CHAIN COUNTER
SETTINGS MENU - CALIBRATION - SET MEASURE
Use this option to select the unit of measurement relative to measurement of chain
lowered.
SETTINGS MENU - CALIBRATION
Use this option to calibrate the chain counter according to the windlass it is mounted
on.
SET MEASURE
SET VALUE:
FEET
METERS
CALIBRATION
SET MEASURE
GYPSY LAP
MAGNETS NUMBER
FREE FALL
EXIT
Selectable options: METERS or FEET. (default: METERS).
Use this option to set the measurement of the chain in one
gypsy lap. To obtain this value, remove the gypsy, wind the
chain around it and then measure its length.
Consult the User's manual of the windlass for more detailed
instructions on how to remove and re-install the gypsy.
It is extremely important that the value set for GYPSY LAP is precise as it affects the accuracy with which
the length of the lowered chain is measured
GYPSY LAP
F
SETTINGS MENU - CALIBRATION - NUMBER OF MAGNETS
Use this option to set the number of magnets installed on the gypsy.
MAGNETS NUMBER
SET VALUE:
GYPSY LAP
SET VALUE:
Selectable Values: 1 to 16. (default: 1).
If the unit of measurement is set to METERS,
the settable values are from 0.1 to 999.9 cm (default: 10 cm).
GYPSY LAP
SET VALUE:
INC
If the unit of measurement is set to FEET,
the settable values are from 0.1 to 999.0 inc (default: 10 inc).
SETTINGS MENU - CALIBRATION - GYPSY LAP
0.1s - 7s
SET SAIL
FREE FALL
CHAIN UP
SPEED
20M/M
ATTENTION:
auto free fall management must be
activated exclusively with windlasses equipped with
auto free fall system. Refer to the instruction manual
relative to the windlass being used.
ATTENTION:
If auto free fall management is activated,
the "no sensor" signal time will vary depending on the
value entered in the AUTO FREE FALL parameter and
the automatic descent function will be deactivated; the
latter will become active again once free fall manage-
ment is deactivated.
SETTINGS MENU - CALIBRATION - AUTO FREE FALL
Through this management we set the time required by the windlass auto free fall sys-
tem to deactivate itself.
FREE FALL
SET VALUE:
0.5 s
Select the available values: OFF, from 0.1s to 7s. (default: OFF)