QUICK 492G Series Combo Tester

Instruction Manual

Thank you for purchasing our products. Please keep

the instruction manual properly for future reference.

Содержание 492G Series

Страница 1: ...QUICK 492G Series Combo Tester Instruction Manual Thank you for purchasing our products Please keep the instruction manual properly for future reference...

Страница 2: ...Dimensions 4 5 2 Part Descriptions 5 6 Connection 6 7 Parameter Settings 7 7 1 Password Settings 7 7 2 Wrist Strap and Anti static Shoes Settings 8 7 3 Other Interface Settings 9 7 4 Calibration Setti...

Страница 3: ...any problems caused by unauthorized maintenance or modification WARNING Don t install the product in a place where the surface is easy to shake or be impacted as it may damage the product Don t place...

Страница 4: ...est the wearing status of wrist straps and anti static shoes simultaneously individual mode can set to test the wearing status of wrist straps foot rings separately and you can choose to test single w...

Страница 5: ...xed plate With Support column Small fixed plate Working model On line Stand alone Power supply AC coupling adapter DC 8 12V Contact switch output Voltage 400V Max Peak value DC or AC Switch current 10...

Страница 6: ...4 5 Functional Descriptions 5 1 Dimensions Unit mm...

Страница 7: ...5 5 2 Part Descriptions...

Страница 8: ...t be connected to ground The two AGNDs in the six core connector are used to connect the anti static shoes pedal to the shielding end of the tester shielding line and must not be connected to the GND...

Страница 9: ...ing parameters of the tester The default password is 00000000 When finishing the input press Enter on the screen keyboard As shown in Figure 2 Note If the password is correct the New Password and Conf...

Страница 10: ...ts and the near upper and lower limits of the wrist straps and the anti static shoes the upper limit and the lower limit of the wrist straps are 100K 35M and the upper limit and the lower limit of the...

Страница 11: ...se Traditional Chinese and English are supported 3 Working mode support online and stand alone selection 4 Access control signal enable to open the door and enable to close the door When all test item...

Страница 12: ...2 The tester calibration page displays some device calibration values and a instrument calibration button The tester can be calibrated after the calibration instrument is connected 3 After all the set...

Страница 13: ...n the testing pedal and touch the test button on the tester to start the test The center and outer ring electrodes of the button must be touched at the same time and maintained until the test is compl...

Страница 14: ...shall be tested with a standard resistance and all tests shall meet 10 accuracy If the range is exceeded the tester shall be calibrated again 10 2 Calibration Method If the calibration is required pl...

Страница 15: ...ered c Damage caused by failure to follow the use methods and precautions in the manual d Damage caused by disassembly repair and modification of products without authorization of the manufacturer e R...

Страница 16: ...UICK INTELLIGENT EQUIPMENT CO LTD ADD NO 11 FengXiang Road Wujin High Tech Industrial Development Zone Jiangsu China TEL 86 519 86225678 FAX 86 519 86558599 POSTCODE 213167 WEBSITE www quick global co...