Quick-Ohm Küpper & Co. GmbH
Components – Heat Management – Industry Ceramics
- 4 -
User Manual English Controller QC-PC-CO-CH1 20181122
The controller QC-PC-CO-CH1 already holds the default parameters in delivery condition which
allows the usage without any programming. But it is also possible to change the control parameters to
optimize the response characteristics. To adjust these parameters, the controller either has to be
connected with the control unit QC-PC-D-CH1 or a computer. The control unit QC-PC-D-CH1 has a
display, where the control process can be traced at first sight. By an easily understandable menu all
parameters can be adjusted as required. The connection is done by a wire and a 3.5mm jack plug
Important:
The voltage connected at the orange wire
must not be above the maximum
voltage of the TEC. This value you can get from our homepage.
100%
Heat parameter
maximum Heating
70%
Heat parameter
minimum heating
20%
Heat parameter
maximum cooling
100%
Heat parameter
minimum cooling
0%
-100%
0%
Heat voltage
Cool voltage
current temperature
Range heating
Range cooling
Temperature
nominal value
Hysteresis
Depiction of the control characteristics
Fig. 4: