AFTER-USE

Flood Gate Maintenance Instructions

1.   Return the horizontal and vertical operating mechanisms to their closed position.

2.   Remove the unit from its position.

3.   Remove the sleeve and examine for damage caused by stress, use or wear and tear.  

      Repair or replace as necessary.

4.   The sleeve can be hand washed in warm water up to 104° F (40° C). Rinse in cold water and hang 

      to dry in shaded area. DO NOT TUMBLE DRY.

5.   Dry off excess moisture from the metal frame.  Examine for damage caused by stress, use or wear and 

 

  tear.  

Apply rust proofing oil or grease to all expandable mechanisms.

6.   Once all parts of the unit are dry, the unit can be stored for future use.

Storing your Flood Gate

1.   Store the unit in a secure location and only allow access by a responsible adult.

2.   The unit should be stored in its closed and upright position.  DO NOT STORE IN AN EXPANDED STATE.

3.   Store the unit and its accessories in a dry and well ventilated area.  DO NOT STORE IN  

  DIRECT SUNLIGHT.

4.   DO NOT EXPOSE THE PRODUCT TO EXTREME TEMPERATURES AND KEEP AWAY FROM  

  OPEN FLAMES.

5.  Place the unit in storage in it’s normal upright position, keeping the sleeve separate & flat to 

 

  maintain it’s shape.

6.   If you are storing more than one unit and do not intend on using the original packaging, the gates must 

 

  be stored face to face (The face as shown in Diagram A).

7.   DO NOT STORE FACE TO BACK OR BACK TO BACK AS THIS CAN DAMAGE THE PRODUCTS.

8.   Review the unit and its mechanisms periodically to ensure that the conditions of storage have not  

  reduced its effectiveness.

TERMS & CONDITIONS

Flood Gate is intended to be used as outlined in this document and other Absorbent Specialty Products (ASP) literature. Data and 

information provided in this document is for general information purposes only. Conditions for each use of the Flood Gate will vary 

and are beyond the control of ASP. ASP cannot guarantee desired results. When purchasing this product from ASP, you agree to as

-

sume all risks that may arise from ownership, installation, and use of the Flood Gate and agree to release ASP from any and all claims 

brought by any person or entity against ASP related to and/or arising from your ownership, installation, and/or use of the Flood Gate. 

ASP shall not be liable for any improper or incorrect ownership, installation or use of this product and assumes no responsibility for 

anyone’s ownership, installation or use of this product. In no event shall ASP be liable for any direct, indirect, incidental, special, ex

-

emplary or consequential damages (including, but not limited to: procurement or substitute goods or services; loss of use or profits; 

or business interruption) however caused and on any theory arising in any way out of the use of this product, even if advised of the 

possibility of such damage. This disclaimer of liability applies to any damages, injury or death, whether based on alleged breach of 

contract, tortuous behavior, negligence or any other cause of action, including and not limited to damages or injuries caused by any 

failure of performance, error, omission, defect or delay in operation.

LIMITED WARRANTY

ASP warrants this product and components to be free from defects in material and workmanship for a period of one (1) year from 

date of shipment. If within the term of this warranty, if any Flood Gate component is found to be defective upon inspection by an 

authorized Flood Gate representative, ASP will replace or repair, at ASP’s discretion, any part found to be defective. Unauthorized 

modification of this product voids this limited warranty. The neoprene sleeve is considered a “wear-item” and is not covered under 

this warranty. Replacements can be purchased from ASP.  Moving parts must be properly maintained prior to storage.  

To make a claim under this warranty, contact ASP at this address:

Absorbent Specialty Products | 1 John C. Dean Memorial Blvd. | Cumberland, RI 02864 | 888-761-4405 | [email protected]

Содержание Flood Gate

Страница 1: ...M A N U A L THE NEXT GENERATION IN FLOOD PROTECTION TM ...

Страница 2: ...e Rails Preparing the Opening 8 Stanchions Laying Out the Hole Location 10 Boring the Holes for the Stanchion Base 10 Assembling the Angle Brackets to the Base 11 Preparing the Ground Surface and Base Recess 11 Inserting Base Assemblies 12 General Maintenance and Installation 13 After Use 14 Terms Conditions Warranty 14 Table of Contents TESTED APPROVED The Flood Gate is Kitemark certified ensurin...

Страница 3: ...of maintaining a seal A FLOOD GATE ADJUSTED FROM REAR OF PRODUCT Shown without neoprene cover WHAT THEY ARE MADE OF A 1 Steel Tube Frame provides the support structure B 1 8 Front Steel Flat Sheets block take the weight of the water Please note Flat sheet is only connected on one side of the gate to allow for expansion C 2 ton Scissor Jack expands creates a secure fit within door frame D Neoprene ...

Страница 4: ...ns Operations Manual 17mm Ratchet Wrench Box components Flood Gate Size 25in 30in Max Expansion 34in Height 26 5in Flood Gate Size 30in 35in Max Expansion 39in Height 26 5in Flood Gate Size 35in 40in Max Expansion 44in Height 26 5in Flood Gate Size 40in 45in Max Expansion 49in Height 26 5in Flood Gate Size 45in 50in Max Expansion 54in Height 26 5in Note For openings wider than 50in stanchions must...

Страница 5: ...ough 1 32 mm 1 25 mm may be sufficient as long as the Flood Gate can grip tight This should be measured from the furthest outward point on the door usually the frame but look for threshold at the bottom of the door that often protrudes into the reveal space Note If door opens out you will need a minimum distance of 3in between the Flood Gate and the door to access the jack and bolts with a ratchet...

Страница 6: ...fectiveness It is recommended that expansion be no more than 5 inches 12 7 cm If a larger unit would fit the opening it must be used instead of over extending a smaller unit STEP FOUR Hand tighten each of the 4 downward pressure bolts to a maximum depth of 7 mm to compact the sleeve along the ground see Diagram 3 WARNING DO NOT fully tighten these bolts as this will cause the Flood Gate to rise of...

Страница 7: ...you can sufficiently extend the reveal to allow the barrier to work Use a pair of Side Rails optional to fit to either the reveal or the outer face of the building and provide a solid point to which the Flood Gates can fit into See Example 1 Example 1 Side Rails optional accessory To fit the Flood Gate in a wall where the side walls are not adequate you will need to create a side wall support of s...

Страница 8: ... surface and installation options should be discussed with a qualified architect engineer or contractor General knowledge in concrete construction is necessary for this project It is important that the Side Rails and Stanchions are square to the ground surface and parallel to each other TOP BOTTOM Flood water comes from this side Ground UNDERGROUND Upright Stanchion Base TOP BOTTOM Flood water com...

Страница 9: ...ion bolts on the lower edge of the Flood Gate reducing the amount of horizontal pressure required to secure the Flood Gate in place If you are fastening against a masonry surface use a carbide tipped drill bit Use screws suitable for wood and concrete If threading into wood you need to drill a pilot hole first 90º 90º FRONT VIEW 90º 30 TOP VIEW DOOR STOP JAMB PLATE SIDE RAILS OPTIONAL EXTRA THE 2 ...

Страница 10: ...PERTY OF INSERT COMPANY NAME HERE ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF INSERT COMPANY NAME HERE IS PROHIBITED Be sure screws are flush with the inside surface of the rail leakage Failure to do so could result in damage to the neoprene sleeve A A B B C C D D 4 4 3 3 2 2 1 1 DO NOT SCALE DRAWING flush SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 4 WEIGHT REV DW...

Страница 11: ...tical to ensure proper alignment of the Flood Gate panels J I J BORING THE HOLES FOR THE BASE 40 B 40 B 40 B 40 B 40 B 3 3 8 200 A This illustration is an Example of an opening of 14 ft for A Using 5 Flood Gates each stanchion or dimension B is positioned at their respective center lines NOTE The 3 in 76 2 mm set back dimension to the center line of the bored holes is critical to insure proper ali...

Страница 12: ...ING ANCHOR ASSEMBLY ANCHOR ASSEMBLY TOWARDS FLOOD WATER A A B B C C D D 4 4 3 3 2 2 1 1 DO NOT SCALE DRAWING square SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 4 WEIGHT REV DWG NO C SIZE TITLE NAME DATE COMMENTS Q A MFG APPR ENG APPR CHECKED DRAWN FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL ANGULAR MACH BEND TWO PLACE DECIMAL THREE PLACE D...

Страница 13: ...crete to maintain maximum strength 3 Ensure the top edge of angle brackets are flush with the surface of the ground Do not remove the clamps and angle brackets for at least 24 to 36 hours depending on the temperature humidity and soil mechanics to allow concrete to set AIR RELIEF HOLE RIDGED STRAIGHT EDGE CLAMP 4 not included Center line mark on face of Angle Bracket must line up with marks on Rid...

Страница 14: ...oss the anchor plate without damaging the threads See illustration Q 2 These plugs should be flush with the top of the Base and no deeper They should also be re greased periodically and after every use to ensure they will come out when needed Before Installing the Stanchion IMPORTANT To prevent any leaking between the top of the Base and the bottom of the Stanchion there is a machined 3 16 groove ...

Страница 15: ...yond the control of ASP ASP cannot guarantee desired results When purchasing this product from ASP you agree to as sume all risks that may arise from ownership installation and use of the Flood Gate and agree to release ASP from any and all claims brought by any person or entity against ASP related to and or arising from your ownership installation and or use of the Flood Gate ASP shall not be lia...

Страница 16: ...roperty Management Retail Visit us at www quickdams com or call 888 761 4405 Be Prepared Be Protected QD_Flood_Gate_manual MORE 2019 Quick Dam Flood Gate Absorbent Specialty Products All rights reserved No part of this manual may be reproduced distributed or transmitted in any form or by any means without consent from Quick Dam Absorbent Specialty Products ...

Отзывы: