Quick Charge SCP Скачать руководство пользователя страница 9

TROUBLESHOOTING 

 

Symptom 

Cause 

Corrective Action 

When plugged into AC 
power the LED flashes 
red/green, and a 0 on 
display.  

Connected reverse to 
battery, or not connected 
to battery.  
 
 
 
Break in DC cord, or 
connector.  
 
Battery too dead to 
charge. 

Correct polarity, or 
connect to battery. On 
chargers having a black 
and white wire, white is 
positive. 
 
Have a qualified person 
make repair. 
 
Replace. 
 

When plugged into AC 
power the display does 
not come on. 

No AC power.  

Check circuit.  
 
Check extension cord 
for breaks or damage. 

When I put a volt meter 
across the output of the 
charger there is no 
power coming out when 
I plug it in. 

The charger must be 
connected to a battery to 
turn on. 

 

The batteries don’t 
receive a full charge. On 
wet cells, the specific 
gravity will not rise to a 
full reading after the 
charge has completed.  

The charger is too small 
for the battery. 
 
 
 
The charge profile is not 
set correctly. 
 
The cycle needs more 
time.  
 
 
The battery is defective. 

Check that the charger’s 
output is about 10% of 
the amp hour rating of 
the battery. 
 
Recheck the setting. If in 
doubt, contact us. 
 
Set gas/absorption to 

d2

 
 
 
Replace. 

On start up, the LED 
flashes red/yellow. 

Charger and battery 
voltage mismatch. 

Connect the charger to a 
battery(s) with the same 
voltage rating. 

Содержание SCP

Страница 1: ...argers models SCP SCPX SCS SCSX SCX For Industrial Use Designed for gel wet cell AGM and Lithium Ion batteries Lithium ion applications must be factory programmed Quick Charge Corp 800 658 2841 e mail...

Страница 2: ......

Страница 3: ...When using multiple batteries in a series string cells become uneven during charge and discharge cycles At least once a month perform two charge cycles back to back this will give a chance for cells t...

Страница 4: ...ounded to reduce the risk of electric shock 117 volt chargers are equipped with a grounding type plug 230 volt chargers are shipped without a plug Have a qualified electrician install a properly groun...

Страница 5: ...oss the battery terminal or battery top Arcing or explosion of the battery can result Do not wear jewelry when working around batteries Arcing can cause severe burns The tops of the batteries and batt...

Страница 6: ...re the AC cord DC output leads terminals connectors or clamps are all in good working condition Do not use the charger if there are any signs of stress or damage or if wires are cut or have damaged in...

Страница 7: ...s a three stage profile for AGM batteries Bulk charging absorption cycle and maintenance F5 is for Lithium ion batteries and must be pre programmed at the factory The adjustments are d0 standard gassi...

Страница 8: ...p at the desired profile The display will stop flashing and remember the setting Unplug AC power and reconnect the battery When powered back up the display will flash the changed setting and the charg...

Страница 9: ...volt meter across the output of the charger there is no power coming out when I plug it in The charger must be connected to a battery to turn on The batteries don t receive a full charge On wet cells...

Страница 10: ...e charger blows the branch circuit fuse circuit breaker a short while after being switched on The branch circuit is too small Relocate charger to a branch circuit with a heavier rating or remove other...

Страница 11: ...s did not reach minimum voltage requirements and the charger bulk timed out The batteries are too big for the charger The batteries have defective cells and cannot make minimum voltage NOTE An occasio...

Страница 12: ...zed by Quick Charge or if the charger or component have been subjected to misuse negligence or harsh environmental conditions Except those chargers designed for such conditions If returning the charge...