Quick Charge OB Series Скачать руководство пользователя страница 7

These switch setting are for those chargers with a date code of  
JUN21 and older.  

Definitions: 
 
Standard deep cycling

 means regularly discharging your batteries 

to about 50% or more.  
 

Shallow cycling

 means using your batteries for short periods of 

time, rarely subjecting them to a standard or deep discharge, or that 
the batteries are used often, but for short periods of time, and 
recharged often. 
 

AGM 

are sealed batteries not requiring water, they are also 

referred to as 

Gel

 many times, although not officially a Gel 

battery.  

 
Float

 means the charge cycle ends with the charger not turning off, 

but indefinitely putting in a small current to hold the voltage to a 
minimum level.  
 

Maintain

 means the charger turns off at the end of the cycle, but 

will monitor the batteries and turn back on should the voltage drop 
to a minimum level preventing  the batteries from going 
completely dead. This setting is recommended for batteries left 
unattended for long periods of time. 
 
 

 

Содержание OB Series

Страница 1: ...OB OBXU On Board Battery Chargers Including OB2425GN OB2425SJ For Industrial Use Designed for gel wet cell AGM and Lithium Ion Batteries Quick Charge Corp 800 658 2841 e mail info quickcharge com www...

Страница 2: ...ady red When the cycle is 80 complete it will turn yellow and finally green when cycle is complete If the profile is set to float the battery s after complete charge the LED will flicker green If the...

Страница 3: ...ounded to reduce the risk of electric shock 117 volt chargers are equipped with a grounding type plug DO NOT USE THIS CHARGER ON A TWO POLE UNGROUNDED OUTLET OR ATTEMPT TO BREAK OFF THE GROUND PRONG F...

Страница 4: ...excessive self discharge and flow of current between the battery post and frame With wet cell batteries maintain the proper electrolyte level by adding water when necessary Never allow the electrolyte...

Страница 5: ...charger will cause damage to batteries charger and can create an explosive atmosphere Make sure the AC cord DC output leads terminals connectors or clamps are all in good working condition Do not use...

Страница 6: ...mechanism of the equipment when the charger is plugged in so it cannot be moved and cause damage to the AC cord and receptacle These wires do not have to be connected for the charger to work REMOTE LE...

Страница 7: ...arged often AGM are sealed batteries not requiring water they are also referred to as Gel many times although not officially a Gel battery Float means the charge cycle ends with the charger not turnin...

Страница 8: ...These switch settings are for those chargers with a date code of JULY21 and newer...

Страница 9: ...Use this setting for long periods of inactivity or if it is just preferred over float mode Sometimes selecting the wrong switch setting will result in under or over charged batteries Other times there...

Страница 10: ...n DC cord or connector Battery too dead to charge Correct polarity or connect to battery Have a qualified person make repair Replace When plugged into AC power the LED does not come on No AC power Che...

Страница 11: ...e cause of premature battery failure The charger blows it s fuse or branch circuit fuse circuit breaker as soon as it s switched on Charger is shorted Contact factory The charger blows the branch circ...

Страница 12: ...red item will then be returned freight prepaid by Quick Charge This warranty is void if the charger or component have been altered changed or repaired by anyone not authorized by Quick Charge or if th...