Special notice: 
a.

In  the  process  of  clean  the  active  optical  fiber  connector,  you  should  avoid
direct shining at eye, which will cause permanence burn!!!!

b.

Use proper energy to install the active optical connector, or the ceramic tape
in  the  adaptor  will  lead  to  break.  Once  the  ceramic  tape  is  broken,  the
optical output power will decrease rapidly. And turn the active optical fiber
connector slightly, the optical output power changes obviously.

c.

Please  operate  the  optical  fiber  under  the  condition  of  shut  off  the  pump
laser.  Or  the  high  output  power  will  lead  to  burn  the  joint  of  the  optical
output fiber, which will cause the output power decrease.

Equipment  changes  result  in  some  parts  does  not  match  with  this  manual,  without  prior 

notice. 

www.questtel.com

[email protected]

EDFA Optical Amplifier

 User Manual

 

L-RF-EDFA-18dBm

Содержание L-RF-EDFA-18dBm

Страница 1: ...L RF EDFA 18dBm User Manual CATV EDFA Optical Amplifier 1550nm 18dBm www questtel com sales questtel com...

Страница 2: ...5 5 External Function Description 6 5 1 Front Panel Description 6 5 2 Rear Panel Description 7 5 3 Displayed Parameter description 8 6 Installation debugging 12 6 1 Unpack and Check 12 6 2 Instruments...

Страница 3: ...le the fiber amplifier is working there is an invisible laser beam from the optical output adapter on the front panel Avoiding permanent harm to the body and eye the optical output should not aim at t...

Страница 4: ...is adjustable attenuation range is 0 3dB Adopt high performance erbium doped fiber high efficiency energy conversion Adopt advanced 32 bit processor coordinate with perfect automatic monitoring syste...

Страница 5: ...on With standard optical fiber and standard optical receiver composed the test link Set 59 PAL D analog TV channel signal at 550MHz frequency range under the specified link loss Transmit digital modul...

Страница 6: ...turn loss Input dB 45 Output dB 45 Pump leakage power Input dBm 30 Output dBm 30 Optical connector type FC APC or SC APC Power supply voltage V AC160V 250V 50 Hz Consumption W 30 Operating Temperature...

Страница 7: ...ormal 4 Output optical power indicator This light turns on when the output optical power is large than 10dBm 5 160 32 Dot matrix LCD screen used to display all the parameters of the machine 6 Display...

Страница 8: ...ng normal So the port should not be aligned to the human body or the naked eyes to avoid accidental injury 4 RS232 interface Used for configuring the network management parameters 5 LAN interface corr...

Страница 9: ...p1 Temper xx x C Temperature of pump1 accurate to 0 1 C Pump1 Tec x xx A Cooling current of pump1 accurate to 0 01 A Pump2 Bias x mA Bias current of pump2 accurate to 1m A Pump2 Temper xx x C Temperat...

Страница 10: ...e factory configuration set content as shown above 3 Alarm Status Input Status xxx xxx LOLOW Very low input optical power alarm xxx LOW Low input optical power alarm xxx HIGH High input optical power...

Страница 11: ...rm xxx LOW Low bias current of pump2 alarm xxx HIGH High bias current of pump2 alarm Xxx HIHIGH Very high bias current of pump2 alarm Pump2 Temper xxx xxx LOLOW Very low temperature of pump2 alarm xxx...

Страница 12: ...W Low 5V DC power supply alarm xxx HIGH High 5V DC power supply alarm Xxx HIHIGH Very high 5V DC power supply alarm Device Temper xxx xxx LOLOW Very low chassis temperature alarm xxx LOW Low chassis t...

Страница 13: ...ably grounding The grounding resistance must be 4 3 Use the digital multimeter to check the supply voltage make sure the supply voltage comply with the requirements and the switch key is on the OFF po...

Страница 14: ...it 1 2 minutes after wash let the connector surface dry in the air 3 Cleaned optical connector should be connected to optical power meter to measure optical output power to affirm whether it has been...

Страница 15: ...put power will decrease rapidly And turn the active optical fiber connector slightly the optical output power changes obviously c Please operate the optical fiber under the condition of shut off the p...

Страница 16: ...ck 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never...