Quest Technologies M-27 Скачать руководство пользователя страница 7

 

Battery Indicator: 8-hour battery life, 1 week data retention 
 
Calibrator:           External calibrator 

 

Temperature:       -15° to 50°C operating; -40° to 60°C storage (battery removed). 

 

Humidity:            0 to 95% non-condensing 

 

Magnetic Field Effects:

 

Negligible below 50 Oersteds at 50 to 60 Hz

 

Size:                    5 ½  x 2 ¾  x 1 3/8 inches

 

(140 x 70 x 40 mm) 

 

Weight:                14 ounces (400 grams) 

 

Construction:         Cast aluminum housing with tamper-, water-, and dust-resistant security cover. 

 

 
GENERAL DESCRIPTION 

 

The microprocessor based M-27 Noise Logging Dosimeter can be used as a personal noise 

dosimeter, an area monitor, and as a noise survey instrument. It can be used to check compliance with the 
requirement of the Occupational Safety and Health Administration (OSHA), or as a community or 
Department of Defense noise logging dosimeter.

 

 
The M-27 simultaneously monitors multiple noise functions for 3 separate dosimeters as well as 

sound, peak, and maximum levels, and run, pause, upper limit, and real or elapsed times. It also stores, 
displays, and prints out data for 16 different events.

 

 
The readings can be taken at any time without destroying or resetting the data. Even turning the 

unit off will not destroy the internal memory.

 

 
A water- and dust-resistant cover protects the unit from the elements and against tampering.

 

 
The unit is small enough to be placed in a shirt pocket or on a belt with the microphone clipped to 

the shirt collar or on the shoulder. The microphone can be attached to a bracket for use as a sound level 
meter. Or the unit can be mounted on a tripod for area surveys.

 

 

The M-27 is powered by a single 9-volt transistor battery with an 80-hour battery life. A low 

battery indication is displayed 8 hours before the end of life of an alkaline battery. 

 

PRINCIPLES OF OPERATION 

 
 

General

 

 

The M-27 Noise Logging Dosimeter uses an 8 mm omnidirectional ceramic microphone buffered 

by a high impedance FET input stage. 

 

The electronics utilizes low power circuitry for long battery life, maximum stability, and high 

reliability over a wide range of environmental conditions. A block diagram of the M-27 is shown in Figure 
3. 

 

Weighting Characteristics 

 

The M-27 has both "A" and "C" weighting characteristics as shown in Figure 4. For OSHA and 

most noise measurement requirements, the "A" weighting should be used. The "A" weighting has a 
response similar to the human ear. The "C" weighting is used for measuring noise reduction in hearing 
protectors and for other scientific purposes. 

 

 

Содержание M-27

Страница 1: ...Microphone Replacement 18 Calibration and Maintenance 18 Daily Calibration 18 Altitude Corrections 19 OPERATING PROCEDURE 19 As a Personal Noise Dosimeter 19 As an Area Monitor 20 As a Survey or Event...

Страница 2: ...r is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connec...

Страница 3: ...75 80 85 or 90 dB 2 ranges of 35 126 or 50 146 dB A or C frequency weighting Fast or slow time constant Upper limits of 90 115 or 140 dB 12 or 24 hour clocks 8 different unit numbers Text graph or bot...

Страница 4: ...IME data If the total time is less than 30 minutes the co lon will blink if the key is held down and the time shown is in minutes and seconds If the colon stays on the time shown is in hours and minut...

Страница 5: ...n it should be rechecked PAUSE Resets the calibration level Hold key down until the RESET display shows CAL Using a Printer The printout Figure 2 can include a heading a summary of the data event data...

Страница 6: ...hing printers or computers without destroying data See Printer Setup page 32 NOTE Internal switches 1 and 2 are read only when the unit is RESET SPECIFICATIONS Standards ANSI S1 4 1983 type 2 ANSI S1...

Страница 7: ...ing the unit off will not destroy the internal memory A water and dust resistant cover protects the unit from the elements and against tampering The unit is small enough to be placed in a shirt pocket...

Страница 8: ...e The same as the pause mode except the data necessary to compute Lavg Leq Dose TWA SEL Peak Max Run Time Upper Limit as well as Event data is accumulated Compute Mode If a key has been pressed in the...

Страница 9: ...y Test Press any key If the battery is low LOB AT will be displayed in the upper left corner of the display If the battery has at least 8 hours life LOBAT will be off If LOBAT is displayed after a day...

Страница 10: ...the microphone Carefully insert the microphone in the microphone adaptor and place the adaptor in the calibrator Make sure the microphone is inserted all the way in the adaptor and the adaptor rests...

Страница 11: ...ck of unit and clip microphone to the microphone bracket The microphone clip may be removed and the microphone screwed to the bracket before the bracket is mounted to the case see Figure 7 3 Mount the...

Страница 12: ...nstrument the microphone should be mounted on the MB 1 microphone bracket see Figure 7 It may either be clipped to the bracket or the clip removed and the microphone screwed to the bracket The bracket...

Страница 13: ...d or only selected data if desired It is possible to change the printout in the middle to obtain for instance a 10 minute histogram for part of the time and a 1 minute histogram for another The M 27 r...

Страница 14: ...hange the time base on the histogram in the middle of a printout see Figure 14 for example and page 31 for details If only TEXT was selected on the internal switches the graph portion would be omitted...

Страница 15: ...ributions two with a Time constant and two without If the M 27 is used for community or 3 dB industrial monitoring the printout will contain much more information than would a data logger with a singl...

Страница 16: ...han 25 feet long and may be more than is needed If only the data for hearing conservation is required press CODE HL3 until the LTL annunciator is displayed Pressing PRINT will reduce the data by one h...

Страница 17: ...ally ON graph and text Positions 5 and 6 control the last 2 characters line Most printers work with both ON Positions 7 and 8 are undefined for parallel Computer Connections The M 27 can send its data...

Страница 18: ...dB a low threshold level of 80 dB 115 dB upper limit level A frequency weighting the 50 dB to 146 dB range a SLOW time constant and a 12 hour clock If the display is a 3 digit code then the first num...

Страница 19: ...Off On 4 dB On Off 5 dB On On 6 dB SWITCH 2 Positions 1 2 3 4 HTL LTL Off Off Off Off 70 dB none Off Off Off On 70 dB none Off Off On Off 75 dB none Off Off On On 80 dB none Off On Off Off 85 dB none...

Страница 20: ...code in the first digit column in Table 2 The clock is 12 hours The 0 means the time constant of weighting is A the range is 50 146 the upper limit is 115 dB and the time constant is Slow The first E...

Страница 21: ...e changed when the unit is operating the change will be ignored Switch 3 is read at the start of a printout It may be changed to allow printouts to different printers or computers without destroying t...

Страница 22: ...TL Dose and TWA If Run Time is less than eight hours TWA is less than Lavg if Run Time is more than eight hours TWA is greater than Lavg The SEL is greater than Leq The 3 dB Dose is greater than the L...

Страница 23: ...ple Estimating TWA from Lavg A short term sample can be used to estimate worker exposure even if the workday is other than eight hours by adding or subtracting a correction factor from the Lavg readin...

Страница 24: ...rion level Peak noise levels greater than the range of the instrument are clipped and act as if they were at the maximum level of either 146 dB on the 50 dB range or 126 dB on the 30 dB range Minimum...

Страница 25: ...ll for a new RA number Send it prepaid and properly packed in the original shipping carton directly to Quest Technologies 1060 Corporate Center Drive Oconomowoc WI 53066 U S A Repair or replacement wo...

Отзывы: