Installation, Operation and Maintenance Instructions

  

2

www.QuestOnTheJob.com

[email protected]

Quest PowerDry 1300 

Installation, Operation and Maintenance Instructions

  

Table of Contents

Safety Precautions ............................................. 3 

1.  Safety Certifications

 ....................................... 4 

2.  Specifications 

 ............................................... 4 

3. Handle Installation ........................................ 4
4.   Operation .....................................................  4 
  4.1 Transporting ............................................ 5
  4.2 Electrical Requirements ........................... 5
  4.3 Condensate Removal ............................... 5
  4.4 Ducting ................................................... 5
  4.6 POWER Button ........................................ 5
  4.7 PURGE Button ........................................ 5
  4.8 Hour Meter ............................................. 6
  4.9 HOURS Button ....................................... 6
  4.10 DEFROST Light ..................................... 6
5. Maintenance ................................................. 6
  5.1 Air Filter .................................................. 6
  5.2 Storage .................................................... 6
6  . Service .......................................................... 7
  6.1 Technical Description .............................. 7
  6.2 Troubleshooting ....................................... 7
  6.3 Air Mover ................................................ 9
  6.4 Thermistor ............................................... 9
  6.5 Condensate Pump ................................... 9
  6.6 Float Safety Switch ................................ 10
7. Options and Accessories ............................. 10
8. Wiring Diagram .......................................... 11
9. Service Parts ................................................ 12
Warranty ......................................................... 13

quest

quest

Содержание PowerDry 1300

Страница 1: ...is built around tested engineering principles and has passed a thorough inspection for quality of workmanship and function 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free 1 866 933 7476 www...

Страница 2: ...le Installation 4 4 Operation 4 4 1 Transporting 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 5 4 4 Ducting 5 4 6 POWER Button 5 4 7 PURGE Button 5 4 8 Hour Meter 6 4 9 HOURS Button 6 4 10 D...

Страница 3: ...ACE THAT IS PROTECTED FROM RAIN AND FLOODING Install the unit with space to access the back or side panels for maintenance and service DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE Avoid di...

Страница 4: ...0 Lay Flat Options Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Dimensions Width 20 Depth 17 Height 30 Weight 82 lbs 3 Handle Installati...

Страница 5: ...ondensation 4 4 Ducting A wire duct collar is supplied to allow 10 lay flat duct to be attached to the Quest PowerDry 1300 outlet Lay flat plastic ducting is available see accessories table page 6 To...

Страница 6: ...egularly The standard filter is a MERV 8 high efficiency filter Operating the unit with a dirty filter will reduce the dehumidifier s capacity and efficiency and may cause the compressor to cycle off...

Страница 7: ...ure to drop It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates The evaporator operates in a flooded condition which means that all the evaporator tubes conta...

Страница 8: ...mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cyc...

Страница 9: ...ermistor 1 Unplug the dehumidifier 2 Remove the front housing 3 Cut cable ties and remove insulation and aluminum tape 4 Remove control panel 5 Unthread thermistor from control housing grommet 6 Detac...

Страница 10: ...To replace the condensate pump 1 Unplug the unit 2 Remove the front housing 3 Unplug the pump wires from the wire harness 4 Remove the condensate hose and the one screw attaching the pump bracket to t...

Страница 11: ...nd Maintenance Instructions quest quest Figure 7 8 Wiring Diagram WHT BLK 5 GRN GRN 14 BLK 5 GRN 13 BRN 12 BLK 16 WHT 2 WHT 7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WH...

Страница 12: ...2 03 8 Compressor 1 4029567 9 Thermistor Probe 1 4034716 02 10 Capacitor Impeller 6 0 F 1 4033031 03 11 Hex Bolts 1 4 20 x 1 50 6 1154013 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 G...

Страница 13: ...se upon request by use of the warranty card or other reasonable and reliable means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from mi...