Quest Engineering PB-4120 Скачать руководство пользователя страница 6

4

PB-4120

Front Panel Controls

1. Handle

 - For easy transport while carrying, 

or while rack mounting, the amplifier features 
two heavy duty die cast handles located 
conveniently on the left and right side of the 
front panel. 

2. Fan Vent

 - The amplifiers stay cool thanks 

to their twin, forced-air cooling vents. Cool 
air is drawn through the front panel fan filters, 
reducing the temperature of the internal 
components while forcing the heat out the 
rear vents.  

3. Clip LED

 - The CLIP segment lights 

whenever the channel is outputting signal 
at full strength. For the best signal-to-noise 
ratio, the right (PEAK) segment should light 
occasionally during peak levels; if it lights 
frequently, you may be overloading the 

PB-4120

 and a distorted (“clipped”) signal is 

probably being output. 

4. Protection LED

 - This goes on for 

approximately one second, whenever the 

PB-4120

 is powered on and then turns off 

. The Protection LED will also light when 
overheating or other severe problems occur.  
It is normal for the Protection LED to fade 
slowly when the amp is powered off.  When 
lit, no signal is provided to any connected 
speakers, thus muting them and preventing 
any “thump” from occurring.

5. Signal LED

 - The front panel LED 

indicators continuously monitor the power 

PROTECT

CH 1

CH 2

CH 3

CH 4

CLIP

-20 dB

SIGNAL

POWER

POWER AMPLIFIER

PB-4120

ON

OFF

output level for the corresponding channel.  
The SIGNAL LED lights whenever output 
signal is present.  

6. Power switch

 -  Use this to power the 

Amplifier on or off. The internal LED lights 
whenever the Amplifier is powered on.

Front Panel Controls

1

3

4

5

6

2

Содержание PB-4120

Страница 1: ...PROTECT CH 1 CH 2 CH 3 CH 4 CLIP 20 dB SIGNAL POWER POWER AMPLIFIER PB 4120 ON OFF Owner s Manual PB 4120 ...

Страница 2: ...WARNING ...

Страница 3: ...1 PB 4120 Introduction 2 Features 3 Front Panel Controls 4 Rear Panel Controls 5 Connections 6 System Set Up 7 Output Wiring Guide 8 Specifications 9 BlockDiagram 10 Table of Contents Table of Contents ...

Страница 4: ... Protection LED indicators to help you set the correct operating levels Euro block input and output connectors are provided to insure easy connections and maximum flexibility To keep the amplifiers running cool their designs employ internal wind tunnels with forced air cooling via an internal fan which greatly reduces the chance of thermal and overheating problems Multi stage protection for power ...

Страница 5: ...t for overloading clipping conditions Forced air cooling via internal fan provides reliable performance without thermal and overheating problems Protection circuitry with dedicated LEDs for each channel that guards against overheating or faulty wiring conditions and also prevents thumps when powering on or off This means that you can use the PB 4120 with a single power strip into which a mixer or ...

Страница 6: ...be overloading the PB 4120 and a distorted clipped signal is probably being output 4 Protection LED This goes on for approximately one second whenever the PB 4120 is powered on and then turns off The Protection LED will also light when overheating or other severe problems occur It is normal for the Protection LED to fade slowly when the amp is powered off When lit no signal is provided to any conn...

Страница 7: ... also be inserted into these inputs but you ll get better signal quality and less outside noise and hum if you use balanced lines The SZ Series accepts input levels of any strength but needs at least 0 dBu to achieve maximum power 3 Link Output Connectors Connect out going signals from these jacks 4 AC input Connect the supplied heavy gauge 3 pin IEC power cable here 5 Euroblock Output connectors ...

Страница 8: ... 0 dB ADJUST LINK CH 3 INPUT OFF ON HPF 400Hz 12 0 dB ADJUST LINK CH 1 INPUT OFF ON HPF 400Hz DESIGNED AND ENGINEERED IN KOREA WARNING DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY SAME TYPE FUSE AVIS RISQUE DE CHOC ELECTRONIQUE NE PAS OUVRIR ATTENTION UTILISER UN FUSIBLE DE RECHANGE MEME TYPE CH 3 COM CH 2 CH 1 12 0 dB ADJUST L...

Страница 9: ...p System setup System setup PM 10 2 CH 4 SPEAKER OUTPUT PUBLIC ADDRESS POWER AMPLIFIER PB 4120 12 0 dB ADJUST LINK CH 2 INPUT OFF ON HPF 400Hz 12 0 dB ADJUST LINK CH 3 INPUT OFF ON HPF 400Hz 12 0 dB ADJUST LINK CH 1 INPUT OFF ON HPF 400Hz DESIGNED AND ENGINEERED IN KOREA WARNING DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY SAME...

Страница 10: ...ur amplifier Output Wiring Guide 100 V 83 70 V 41 25 V 5 2 COM 4 OHM 100 V 83 70 V 41 25 V 5 2 COM 4 OHM 100 V 83 70 V 41 25 V 5 2 COM 4 OHM 100 V 83 70 V 41 25 V 5 2 COM 4 OHM Output Wiring Guide 4 and 8 Ohm Wiring Guide 25 Volt Wiring Guide 70 Volt Wiring Guide 100 Volt Wiring Guide SHOCK HAZARD SYMBOL WARNING PAY ATTENTION TO THE WARNING SYMBOL AND AVOID ELECTRICAL SHOCK DO NOT HOLD OR TOUCH TH...

Страница 11: ...20kHz brickwall filter 70dB Input Clipping 26dBu Connectors each channel Input XLR jack Output Euroblock Controls AC power switch Channel volume HPF Indicators Power on blue Protection red Signal green for each Ch Cilp red for each Ch Protection Short circuit Thermal Current limit DC offset Current inrush RF protection Turn on Turn off muting Cooling Continuously variable speed fan forced air Tran...

Страница 12: ...10 PB 4120 Block Diagram Block Diagram ...

Страница 13: ...11 PB 4120 ...

Страница 14: ......

Отзывы: