background image

quest

quest

Quest DRY 150

Quest Dry  RDS 10

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

– Read and Save These Instructions –

This manual is provided to acquaint you with 
the dehumidifier so that installation, operation 
and maintenance can proceed successfully. 
Ultimate satisfaction depends on the quality 
of installation and a thorough understanding 
of this equipment. The dehumidifier is built 
around tested engineering principles and has 
passed a thorough inspection for quality of 
workmanship and function.

4201 Lien Rd 

Phone 608-237-8400

Madison, WI 53704 

Toll-Free 1-866-933-7476

www.QuestOnTheJob.com [email protected] 

– Read and Save These Instructions –

Specifications subject to change without notice.

4037498

04/15

1

Quest Dry RDS 10:

•  Roto-mold design
•  80 pints per day at 80ºF/60%RH (AHAM) 

(10 Gallons)

•  5.1 amps of power
•  12-inch recessed wheels
•  Telescoping handle
•  Solid state control panel
•  Multiple ducting options
•  Stackable design
• Lightweight

Water Removal Rate (Pints/Day) 

 

80 pints  

80˚F, 60% (AHAM)

 

quest

quest

Patent    7,246,503

Содержание Dry RDS 10

Страница 1: ...built around tested engineering principles and has passed a thorough inspection for quality of workmanship and function 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free 1 866 933 7476 www Q...

Страница 2: ...3 Operation 4 3 1 Transporting 4 3 2 Electrical Requirements 5 3 3 Condensate Removal 5 3 4 Ducting 5 3 6 POWER Button 5 3 7 PURGE Button 5 3 8 Hour Meter 6 3 9 HOURS Button 6 3 10 DEFROST Light 6 4...

Страница 3: ...power cord If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard The unit shall be installed in accordance wi...

Страница 4: ...th year 100 of Parts of sealed refrigeration system Dimensions Width 20 Depth 20 Height 33 Weight 105 lbs Patent 7 246 503 3 Operation Place dehumidifier inside structure place condensate hose into a...

Страница 5: ...y then be quickly attached to the Quest Dry RDS 10 by snapping the collar over the four exhaust tabs 3 5 Defrost Cycle If the low side refrigerant temperature drops due to excessive frost formation on...

Страница 6: ...acity and efficiency and may cause the compressor to cycle off and on unnecessarily The filter can generally be vacuumed clean several times before needing replacement Replacement filters can be order...

Страница 7: ...hen passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the incoming air and e...

Страница 8: ...sed check pump reservoir 3 Defective compressor capacitor 4 Defective compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on...

Страница 9: ...The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom pl...

Страница 10: ...te reservoir The float safety switch turns off the compressor until the water level lowers and disengages the switch To replace the float safety switch 1 Unplug the dehumidifier 2 Remove the front hou...

Страница 11: ...st Dry RDS 10 Installation Operation and Maintenance Instructions quest quest BLU 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL...

Страница 12: ...Wheel 2 4027138 10 Filter 12 x 12 x 1 1 4026315 11 Hose 1 4 ID x 33 long 1 4024916 12 Coupling Body 1 4 Tube 1 4026306 13 Coupling Insert 1 4 Tube 1 4026986 14 Cord 1 4032297 15 Control Board 1 402676...

Страница 13: ...on request by use of the warranty card or other reasonable and reliable means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse...

Отзывы: