Smart Module Series
SC200L_Series(Dual-band Wi-Fi)_Hardware_Design 95 / 111
7.7. ESD
If the static electricity generated by various ways discharges to the module, the module maybe damaged
to a certain extent. Thus, please take proper ESD countermeasures and handling methods. For example,
wearing anti-static gloves during the development, production, assembly and testing of the module;
adding ESD protective components to the ESD sensitive interfaces and points in the product design.
The following table shows the electrostatic discharge characteristics of the module.
Table 53: ESD Characteristics (Temperature: 25 °C, Humidity: 45 %)
WCDMA B2
TBD
TBD
TBD
-104.7 dBm
WCDMA B4
TBD
TBD
TBD
-106.7 dBm
WCDMA B5
TBD
TBD
TBD
-104.7 dBm
WCDMA B8
TBD
TBD
TBD
-103.7 dBm
LTE-FDD B1 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
LTE-FDD B2 (10 MHz)
TBD
TBD
TBD
-94.3 dBm
LTE-FDD B3 (10 MHz)
TBD
TBD
TBD
-93.3 dBm
LTE-FDD B4 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
LTE-FDD B5 (10 MHz)
TBD
TBD
TBD
-94.3 dBm
LTE-FDD B7 (10 MHz)
TBD
TBD
TBD
-94.3 dBm
LTE-FDD B8 (10 MHz)
TBD
TBD
TBD
-93.3 dBm
LTE-FDD B28 (10 MHz)
TBD
TBD
TBD
-94.8 dBm
LTE-TDD B38 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
Test Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
±5
±10
kV
All Antenna Interfaces
±5
±10
kV
Other Interfaces
±0.5
±1
kV