M10 Hardware Design
@power level #10,Typical 182mA
@power level #19,Typical 125mA
EGSM 900
@power level #5 <350mA,Typical 300mA
@power level #10,Typical 175mA
@power level #19,Typical 125mA
DCS 1800
@power level #0 <300mA,Typical 240mA
@power level #10,Typical 135mA
@power level #15,Typical 120mA
PCS 1900
@power level #0 <300mA,Typical 230mA
@power level #10,Typical 128mA
@power level #15,Typical 115mA
DATA mode, GPRS ( 1 Rx, 4 Tx ) CLASS 12
GSM850
@power level #5 <660mA,Typical 610mA
@power level #10,Typical 390mA
@power level #19,Typical 200mA
EGSM 900
@power level #5 <660mA,Typical 610mA
@power level #10,Typical 380mA
@power level #19,Typical 200mA
DCS 1800
@power level #0 <530mA,Typical 500mA
@power level #10,Typical 350mA
@power level #15,Typical 200mA
PCS 1900
@power level #0 <530mA,Typical 525mA
@power level #10,Typical 380mA
@power level #15,Typical 210mA
Class 12 is the default set when the module works at data translation mode, the module can also
work at class 10 and class 8 which are configurable through AT command.
5.6 Electro-static discharge
Although the GSM engine is generally protected against Electrostatic Discharge (ESD), ESD
protection precautions should still be emphasized. Proper ESD handing and packaging procedures
must be applied throughout the processing, handing and operation of any application using a
module.
The measured values of module are shown as the following table:
Table 36: The ESD endure statue measured table (Temperature: 25
, Humidity: 45 %)
℃