GNSS Module Series
LG69T(AM,AS)_EVB_User_Guide 16 /
45
4
Communication via QCOM Tool
This chapter explains how to use the QCOM software tool to communicate with the module via the Micro-
USB interface. For more information, see
document [1] QCOM User Guide
.
To establish communication with the GNSS module via QCOM tool:
Step 1:
Connect the EVB and the PC with a Micro-USB cable via the Micro-USB connector. Flip the
Power switch (S101) to
ON
position to power on the EVB.
Step 2:
View the USB port numbers in the PC OS system Device Manager.
Figure 4: USB Ports
Step 3:
Install the QCOM tool provided by Quectel. The QCOM interface for COM port setting is shown
in the figure below (default baud rate: 460800 bps
1
).
Figure 5: QCOM Interface for COM Port Setting
Step 4:
Select the correct “
COM Port
) and correct “
Baudrate
”.
Step 5:
C
lick “
Open Port
” to establish communication with the EVB, as shown in
Interface for COM Port Setting
The NMEA or RTCM message output by the module will be
displayed on the QCOM tool interface, as shown in the figures below.
1
UART interface default settings may vary depending on software versions.