Wi-Fi&Bluetooth Module Series
FC800L_Hardware_Design 43 / 50
4.6. Electrostatic Discharge
Static electricity occurs naturally and it may damage the module. Therefore, applying proper ESD
countermeasures and handling methods is imperative. For example, wear anti-static gloves during the
development, production, assembly and testing of the module; add ESD protection components to the
ESD sensitive interfaces and points in the product design.
Table 18: Electrostatics Discharge Characteristics (25 °C, 45 % Relative Humidity; Unit: kV)
Tested Interfaces
Contact Discharge
Air Discharge
Unit
VBAT
、
GND
2
12
kV
ANT_BT
、
ANT_WIFI
5
10
kV
Other Interfaces
2
2
kV