ETM Management AT commands
The following commands are developed for the Eseye Telemetry Module (ETM). For information about
ETM, see
About the Eseye Telemetry Module
ETMCFG – read and write configuration file values
Read and write configuration file values. For information about the configuration file parameters, see
Using the Quectel BG96 module configuration file
Type
Syntax
Response
Write
AT+ETMCFG=[<
cmd
>,][<
section
>,<
parameter
>[,<value>]]
where:
<
cmd
>
is the command in lowercase, either:
•
save
– saves the current configuration values as a new version. After
saving, you must reboot the modem to apply the changes.
Use
AT+ETMRESET
to reboot the modem.
•
show
– returns the entire current configuration file content. The
response is sent as multiple URCs, with each line beginning
+ETMCFG
.
•
get
– returns the current configuration value for the requested
parameters.
•
default
– resets the configuration file values to the default
firmware values in the factory settings. After resetting to default,
send the
save
<cmd> to keep the default settings, then reboot the
modem.
•
revert
– undoes any changes to the values in the configuration file
up until the last save. If you want to keep the reverted values, send
the
save
<cmd>, then reboot the modem.
If you do not supply <cmd>, the value is applied to the configuration file in
the following format:
AT+ETMCFG=<
section
>,<
parameter
>,<value>
where:
section
is the configuration file section,
parameter
is the
parameter name, and
value
is the new parameter value.
OK
or
ERROR
Examples
AT+ETMCFG=get,mqtt,port
8883
OK
AT+ETMCFG=get,mqtt,urcautoformat
1
33
Eseye-enabled Quectel BG96 module Developer Guide v1.8
ETM Management AT commands