NB-IoT Module Series
BC26 AT Commands Manual
BC26_AT_Commands_Manual 37 / 73
Example
AT+CPSMS=1,,,"01000011","01000011"
OK
AT+CPSMS?
+CPSMS:1,,,"01000011","01000011"
OK
AT+CPSMS=?
+CPSMS:(0-2),,,( "00000000"-"11111111"), ("00000000"-"11111111")
OK
2.19. AT+CEDRXS eDRX Setting
The write command controls the setting of the UEs eDRX parameters. The command controls whether
the UE wants to apply eDRX or not, as well as the requested eDRX value for each specified type of
access technology.
The write command also controls the presentation of an unsolicited result code +CEDRXP:
<AcT-type>[,<Requested_eDRX_value>[,<NW-provided_eDRX_value>[,<Paging_time_window>]]] when
<n>=2 and there is a change in the eDRX parameters provided by the network.
A special form of the command can be given as +CEDRXS=3. In this form, eDRX will be disabled and
data for all parameters in the cCEDRXS will be removed or, if available, set to the manufacturer
specific default values.
1 1 1 value indicates that the
timer is deactivated
<Requested_Active-Time>
String
type; one byte in an 8 bit format. Requested Active Time value
(T3324) to be allocated to the UE. The requested Active Time
value is coded as one byte (octet 3) of the GPRS Timer 2
information element coded as bit format (e.g. "00100100" equals 4
minutes). For the coding and the value range, see the GPRS
Timer 2
IE
in
3GPP TS 24.008 [8]
Table 10.5.163/
3GPP TS 24.008
.
See
also
3GPP TS 23.682 [149],
3GPP TS 23.060 [47] and 3GPP TS 23.401 [82]
. The default
value, if available, is manufacturer specific.
AT+CEDRXS eDRX Setting
Write Command
AT+CEDRXS=[<mode>,[,<AcT-type>[,
Response
OK