GV65 User manual
TRACGV65UM001
- 1
5
-
Figure
8.
Typical
Digital
Input
Connection
There
are
two
digital
outputs
on
GV65.
All
are
of
open
drain
type
and
the
maximum
drain
current
is
150
mA.
Each
output
has
the
built
‐
in
over
current
PTC
resettable
fuse.
Figure
9.
Digital
Output
Internal
Drive
Circuit
Table
8
.
Electrical
Characteristics
of
Digital
Outputs
Logical
status
Electrical
characteristics
Enable
<1.5V
@150
mA
Disable
Open
drain
4.
8
.
Digital
Outputs