GV65 Plus User Manual
TRACGV65PUM001
- 14 -
Figure 9.
Typical Ignition Detection
IGN (Pin9) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key “RUN” position as shown above.
An alternative to connecting to the ignition switch is to find a non-permanent power source that
is only available when the vehicle is running. For example, the power source for the FM radio.
IGN signal can be configured to start transmitting information to the backend server when
ignition is on and enter power saving mode when ignition is off.
There are two general purpose digital inputs on GV65 Plus. They are all negative triggers.
Table 8.
Electrical Characteristics of the Digital Inputs
Logical status
Electrical characteristics
Active
0V to 0.8V
Inactive
Open
The following diagram shows the recommended connection of the two digital inputs.
3.9.
Digital Inputs
Queclink