background image

GV310LAU User Manual

TRACGV310LAUUM001

13

5.6. Power Supply Connection

PWR (pin 11)/GND (pin 6) are the power input pins. The input voltage range for this device is

from 8V to 32V. The device is designed to be installed in vehicles that operate on 12V or 24V

systems without the need for external transformers. But it is recommended to use Power

Protection Cable Kit if it is installed in a truck with 24V battery.

Figure 9. Typical Power Connection

5.7. Ignition Detection

IGN (pin 3) is used for ignition detection. It is recommended to connect this pin to the “RUN”

position of the vehicle ignition switch as shown below.

An alternative to connect to the ignition switch is to find a non-permanent power source that is

only available when the vehicle is running, for example, the power source for the FM radio.

IGN signal can be configured to transmit information to the backend server when ignition is on

and enter the power saving mode when ignition is off.

Table 8. Electrical Characteristics of Ignition Detection

Logical State

Electrical Characteristics

Active

5.0V to 32V

Inactive

0V to 3V or open loop

Figure 10. Typical Ignition Detection Connection

5.8. Digital Inputs

There are three general purpose digital inputs on GV310LAU. They all are negative triggers.

Table 9. Electrical Characteristics of the Digital Inputs

Logical State

Electrical Characteristics

Active

0V to 1.2V

Inactive

Open loop

Содержание GV310LAU

Страница 1: ...GV310LAU User Manual TRACGV310LAUUM001 1 GV310LAU User Manual GSM GPRS WCDMA LTE Cat4 GNSS Tracker TRACGV310LAUUM001 Version 1 00...

Страница 2: ...possession Furthermore system validation of this product designed by Queclink within a larger electronic system remains the responsibility of the customer or the customer s system integrator All spec...

Страница 3: ...Getting Started 11 5 1 Opening and Closing the Case 11 5 2 Installing a SIM Card 11 5 3 Installing the Internal Backup Battery 12 5 4 Switching on the Backup Battery 12 5 5 Installation of the Extern...

Страница 4: ...y Installation 14 Figure 7 Switch and ON OFF Position 14 Figure 8 External GPS Antenna of GV310LAU 14 Figure 9 Typical Power Connection 15 Figure 10 Typical Ignition Detection Connection 15 Figure 11...

Страница 5: ...GV310LAU User Manual TRACGV310LAUUM001 5 0 Revision History Revision Date Author Description of change 1 00 2021 07 21 Eden Cao Initial...

Страница 6: ...featured Track protocol The Track protocol supports a wide variety of reports including emergency alarm Geo fence boundary crossings external power supply monitoring and position reports 1 1 GV310LAU...

Страница 7: ...urs Slow flashing GPS chip is searching GPS signal Fast flashing GPS chip has received GPS signal ON Upgrading the device firmware over the air Fast flashing PWR Note 2 No external power and internal...

Страница 8: ...ing check whether all the following items have been included with your GV310LAU If anything is missing please contact your supplier Table 5 GV310LAU Parts List Name Picture Description GV310LAU Locato...

Страница 9: ...IGN Ignition detection input positive trigger 4 RXD The RXD_RS232 5 TXD The TXD_RS232 6 GND Power and digital ground 7 AD3 OUT3 One special I O can be configured as a 0 16V analog input or an open dr...

Страница 10: ...inition Definition Color PIN No Cable PIN No Color Definition OUT2 Yellow 8 16 Brown White AD2 AD3 OUT3 Brown 7 15 Green AD1 IN3 GND Black 6 14 Blue OUT1 TXD White Black 5 13 Orange IN1 RXD Pink 4 12...

Страница 11: ...case is unsnapped To close Place the cover on the bottom at the position as shown above Slide the cover against the direction of the arrow until it snaps 5 2 Installing a SIM Card Install the SIM card...

Страница 12: ...shown as below Internal Battery Switch Figure 7 Switch and ON OFF Position Note The switch must be at the OFF position when the GV310LAU is shipped on an aircraft When the switch is at the OFF positi...

Страница 13: ...h as shown below An alternative to connect to the ignition switch is to find a non permanent power source that is only available when the vehicle is running for example the power source for the FM rad...

Страница 14: ...output with 150mA max drive current Figure 12 Analog Input or Digital out Connection 5 10 Digital Outputs There are three digital outputs on GV310LAU All are of open drain type and the maximum drain...

Страница 15: ...latch the output state during reset Warning Many modern relays come with a flyback diode pre installed internal to the relay itself If the relay has this diode insure the relay polarity connected is...

Страница 16: ...Serial Port UART interface TXD RXD TXD RXD is standard RS232 signal Figure 16 Connection with RS232 Port 5 12 Motion Sensor Direction GV310LAU has an internal 3 axis accelerometer supporting driving b...

Страница 17: ...s Firmly install the device to a reliable surface to prevent falling off Make the side with antenna face sky to have better signal reception Do not install the device under metal surface or in enclose...

Страница 18: ...signal is too weak The device isn t registered to the network Move the device to a place with good network coverage Messages can t be reported to the backend server by network APN is not right Ask th...

Страница 19: ...g antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Federal Communication Comm...

Страница 20: ...operated with minimum distance 20cm between the radiator your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Consult the dealer or an e...

Отзывы: