Figure 10: Example connection for negative Trigger digital inputs
For positive trigger inputs the electrical conditions are:
Table 11: Electrical conditions of positive trigger digital inputs
Logical State
Electrical State
Active 5.0V
to
32V
Inactive
0V to 3V or Open
The example connection is showed as follow:
Figure 11: Example connection for positive trigger digital inputs
3.3.8.
Digital Input without Interrupt
The DIN1 and DIN4 are digital inputs which do not have interrupt. DIN1 is positive trigger
and DIN4 is negative trigger. The sample rate for this digital input is 2 to 24 seconds. Please
note the high sample rate will also result in high power consumption.
Queclink