QUBINO Zwave PLUS LUXY ZMNKAD1 Скачать руководство пользователя страница 2

full white, inclusion/exclusion and reset) are unavailable until function disabled).

 

 

Parameter no. 70 - Overload safety switch

 

The function allows for turning off the controlled device in case of exceeding the defined power

 

for more than 5 sec. Controlled device can be turned back on by capacitive antenna/s or sending

 

a control frame.

 

Values (size is 2-byte dec):

 

• Default value 2300

 

• 0 = function not active

 

• 1 – 2300 = 1 W – 2300 W

 

 NOTE: This functionality is not an overload safety protection, please check chapter

 

Functionalities” for more details.

 

In case of overload the following message will be send towards the controller:

 

COMMAND_CLASS_NOTIFICATION_V5

 

The Alarm V1 type field set to 0x00

 

Notification Type 0x08 and 0x08 (Overload detected)

 

 

IMPORTANT

 

 

When adding the Luxy Smart Switch to a Z-Wave network with a controller

 

supporting Security 2 (S2), the PIN code of the Z-Wave Device Specific Key (DSK) is required.

 

The unique DSK code is printed on the product label and a copy is inserted in the packaging,

 

which must not be lost. Do not remove the DSK from the product. As a backup measure, use

 

the label in the packaging. The first five digits of the key are highlighted or underlined to help the

 

user identify the PIN code portion of the DSK text. The DSK is additionally represented with a QR Code.

 

 

STATEMENT OF PRODUCTS FORM MULTIPLE MANUFACTURES

 

 

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. 
All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the 
network.

 

 

ASSOCIATIONS

 

 

Group ID

 

Name

 

Maximum 

allowed 

nodes

 

Description

 

1

 

Lifeline

 

1

 

Supports following commands:

 

COMMAND_CLASS_DEVICE_RESET_LOCALLY,

 

DEVICE_RESET_

LOCALLY_NOTIFICATION - triggered upon reset, 

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4,

 

SWITCH_MULT

ILEVEL_REPORT_V4 - triggered upon change of brightness, 

 

COMMAND_CLASS_SWITCH_COLOR_V3,

 

SWITCH_COLOR_RE

PORT_V3 - triggered upon change of color, 

 

COMMAND_CLASS_NOTIFICATION_V8,

 

NOTIFICATION_REPO

RT_V8 - triggered upon change of alarm detection state or 
upon current overload detection, 

 

COMMAND_CLASS_SWITCH_BINARY,

 

SWITCH_BINARY_REPO

RT - is triggered when a change of output state of relay 
occurs. 

 

COMMAND_CLASS_METER,

 

METER_REPORT - triggered upon 

energy consumption change according to configuration 
parameters 40 and 42.

 

CONFIGURATION_REPORT – triggered upon a local change of 
the working mode of the four capacitive buttons (see chapter 
5.4)

 

Reserved for communication with the primary

 

gateway/hub. Used to report unsolicited messages to the 
controller.

 

2

 

LEDs 

on/off

 

5

 

Supports the following command:

 

COMMAND_CLASS_BASIC_V2,

 

BASIC_SET_V2 - is triggered 

when a change of output state occurs; LEDs are on/off.

 

3

 

Change of 

brightness

 

5

 

Supports the following command:

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4,

 

SWITCH_MULT

ILEVEL_SET_V4 - is triggered when a change of output state 
occurs; brightness changes.

 

4

 

Change of 

color

 

5

 

Supports the following command:

 

COMMAND_CLASS_SWITCH_COLOR_V3,

 

SWITCH_COLOR_SE

T_V3 - is triggered when a change of output state occurs; 
colour changes.

 

5

 

Relay 

on/off

 

5

 

Supports the following command:

 

COMMAND_CLASS_BASIC_V2,

 

BASIC_SET_V2 - is triggered 

when a change of output state of relay occurs.

 

 

Endpoint 1 (LEDs):

 

Group ID

 

Name

 

Maximum 

allowed nodes

 

Description

 

1

 

Lifeline

 

0

 

Supports following commands:

 

COMMAND_CLASS_NOTIFICATION_V8,

 

NOTIFICATION_

REPORT_V8- triggered upon change of alarm detection 
state

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4,

 

SWITCH

_MULTILEVEL_REPORT_V4 - is triggered when a change 
of output state occurs, brightness changes

 

COMMAND_CLASS_SWITCH_COLOR_V3,

 

SWITCH_COL

OR_REPORT_V3 - triggered upon change of brightness, 

 

  

2

 

LEDs

 

on/off

 

5

 

Supports the following command:

 

COMMAND_CLASS_BASIC_V2,

 

BASIC_SET_V2 - is 

triggered when a change of output state occurs; LEDs 
are on/off.

 

3

 

Change

 

of

 

brightness

 

5

 

Supports the following command:

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4,

 

SWITCH

_MULTILEVEL_SET_V4 - is triggered when a change of 
output state occurs; brightness changes.

 

4

 

Change

 

of

 

color

 

5

 

Supports the following command:

 

COMMAND_CLASS_SWITCH_COLOR_V3,

 

SWITCH_COL

OR_SET_V3 - is triggered when a change of output 
state occurs; colour changes.

 

 

Endpoint 2 (Relay):

 

 

NOTIFICATION COMMAND CLASS

 

 

The Luxy Smart Switch supports the following notification types and events:

 

Notification Type

 

Notification Event

 

Siren (0x0E)

 

Siren active (0x01)

 

Power Management (0x08)

 

Over-load detected (0x08)

 

 

Siren

 

The  device  sends  a  NOTIFICATION_REPORT,  with  the  listed  type  and  event,  when  it  receives  a 
NOTIFICATION_REPORT. 

 

The device can behave in one of two ways:

 

 

When  it  receives  a  NOTIFICATION_REPORT(notificationType=0x08=POWER_MANAGEMENT)  the 
device will start blinking with a yellow color.

 

 

When the device receives any other NOTIFICATION_REPORT, if will start blinking with a red color.

 

The device will continue to do so, until the user puts it back into its default state, which can be done either with Z-
Wave command or by physically touching the buttons of the device, so that a change of output state occurs. There 
is some control of this behaviour, described in the configuration parameters no. 3.

 

When the device receives notification report with State Idle (0x00), it will change state to Idle and stop signalizing 
alarmed state (LEDs stop blinking).

  

 

Power Management

 

In case of exceeding the power value set in parameter 70 Overload safety switch (default 2300 W) for more than 5 
seconds, the Luxy Smart Switch automatically turns off the output and the overload notification is sent (0x08 Over-
load detected).

 

In case the parameter 70 is disabled the Luxy smart switch has a fixed overload safety value of 2400 W to prevent 
any damage to the module. In this case if the active power is greater than 2400 W for 5 seconds or more, the output 
is turned off automatically and the overload notification is sent (0x08 Over-load detected).

 

 

Z-WAVE COMMAND CLASSES

 

ROOT ENDPOINT (LED control):

 

Device Classes:

 

GENERIC_TYPE_SWITCH_MULTILEVEL (0x11)

 

SPECIFIC_TYPE_COLOR_TUNABLE_MULTILEVEL (0x02)

 

 

Supported Z-Wave Command Classes:

 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

 

COMMAND_CLASS_SUPERVISION_V1

 

COMMAND_CLASS_TRANSPORT_SERVICE_V2

 

COMMAND_CLASS_SECURITY_2_V1

 

COMMAND_CLASS_SWITCH_COLOR_V3 [S2]*

 

COMMAND_CLASS_ASSOCIATION_V2 [S2]*

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 [S2]*

 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 [S2]*

 

COMMAND_CLASS_VERSION_V2 [S2]*

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 [S2]*

 

COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 [S2]*

 

COMMAND_CLASS_POWERLEVEL_V1 [S2]*

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4 [S2]*

 

COMMAND_CLASS_SWITCH_BINARY_V1 [S2]*

 

COMMAND_CLASS_BASIC_V2

 

[S2]*

 

COMMAND_CLASS_METER_V4 [S2]*

 

COMMAND_CLASS_CONFIGURATION_V1 [S2]*

 

COMMAND_CLASS_NOTIFICATION_V8 [S2]*

 

COMMAND_CLASS_MULTI_CHANNEL_V4 [S2]*

 

 

ENDPOINT 1 (LED control):

 

Device Classes:

 

GENERIC_TYPE_SWITCH_MULTILEVEL (0x11)

 

SPECIFIC_TYPE_COLOR_TUNABLE_MULTILEVEL (0x02)

 

Supported Z-Wave Command Classes:

 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

 

COMMAND_CLASS_SUPERVISION_V1

 

COMMAND_CLASS_SECURITY_2_V1

 

COMMAND_CLASS_SWITCH_COLOR_V3 [S2]*

 

COMMAND_CLASS_ASSOCIATION_V2 [S2]*

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 [S2]*

 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 [S2]*

 

COMMAND_CLASS_SWITCH_MULTILEVEL_V4 [S2]*

 

COMMAND_CLASS_SWITCH_BINARY_V1 [S2]*

 

COMMAND_CLASS_BASIC_V2

 

[S2]*

 

COMMAND_CLASS_METER_V4 [S2]*

 

COMMAND_CLASS_NOTIFICATION_V8 [S2]*

 

 

ENDPOINT 2 (built-in relay control)

 

Device Classes:

 

GENERIC_TYPE_SWITCH_BINARY (0x10)

 

SPECIFIC_TYPE_POWER_SWITCH_BINARY (0x01)

 

Supported Z-Wave Command Classes:

 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

 

COMMAND_CLASS_SUPERVISION_V1

 

COMMAND_CLASS_SECURITY_2_V1

 

COMMAND_CLASS_ASSOCIATION_V2 [S2]*

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 [S2]*

 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 [S2]*

 

COMMAND_CLASS_SWITCH_BINARY_V1 [S2]*

 

COMMAND_CLASS_BASIC_V2

 

[S2]*

 

COMMAND_CLASS_METER_V4 [S2]*

 

COMMAND_CLASS_NOTIFICATION_V8 [S2]*

 

 

*[S2] Security S2 Command Class

 

 NOTE: This product can be included and operated in any Z-Wave network with other Z-Wave certified devices 

from any other manufacturers. All constantly powered nodes in the same network will act as repeaters regardless 
of the vendor to increase reliability of the network.

 

 NOTE: This device must be used in conjunction with a Security Enabled Z-Wave Controller to fully utilize all 

implemented functions.

 

 NOTE: This device is a security enabled Z-Wave Plus product that can use encrypted Z-Wave Plus messages to 

communicate to other security enabled Z-Wave Plus products.

 

 NOTE:  DSK access via UI

 

Gateways, which implement the S2 and Smart Start security feature, display an input dialog box, with a full or 
partial DSK key. Most of them display a partial DSK (they do not show the PIN code) when the device is included 
with the S2-Authenticated security scheme. When included with the S2-Unauthenticated, some gateways show 
the complete DSK while others perform the complete inclusion process without prompting the user with the 
dialogue. 

 

 NOTE:  MAPPING OF COMMAND_CLASS_BASIC

 

The COMMAND_CLASS_BASIC is mapped into COMMAND_CLASS_SWITCH_MULTILEVEL, on the root endpoint and 
endpoint1. On endpoint2, COMMAND_CLASS_BASIC is mapped into COMMAND_CLASS_SWITCH_BINARY, for 
enabling relay control:

 

On the root endpoint and endpoint1

, the 4 LEDs will be turned ON or OFF after receiving the BASIC_SET 

command:

 

 

they will be turned on, when the device receives a BASIC_SET(Value=0x01-0x063) (1-99%)

 

 

they will be turned on to the last non-zero value, when the device receives a BASIC_SET(Value=0xFF) 

 

 

they will turn off, when the device receives a BASIC_SET(Value=0x00)

 

On endpoint2

, the relay will be turned ON or OFF, after receiving the BASIC_SET command:

 

 

the relay will be turned on, when the device receives a BASIC_SET(Value=0x01-0x063) (1-99%)

 

 

the relay will also turn on, when the device receives a BASIC_SET(Value=0xFF) 

 

 

the relay will turn off, when the device receives a BASIC_SET(Value=0x00) 

 

 NOTE:  Answering on a METER_GET_V1 command:

 

When the device receives a METER_GET_V1 command, it will answer with a METER_REPORT_V4, with the field 
values rateType=1 and scale=0 (kWh).

 

Group 
ID

 

Name

 

Maximum 

allowed 

nodes

 

Description

 

1

 

Lifeline

 

0

 

Supports following commands:

 

COMMAND_CLASS_NOTIFICATION_V8,

 

NOTIFICATION_REPORT_V8 

- triggered upon current overload detection, 

 

COMMAND_CLASS_SWITCH_BINARY,

 

SWITCH_BINARY_REPORT - is 

triggered when a change of output state of relay occurs.

 

COMMAND_CLASS_METER,

 

METER_REPORT - triggered upon 

energy consumption change according to configuration parameters 
40, 42

 

2

 

Relay 

on/off

 

5

 

Supports the following command:

 

COMMAND_CLASS_BASIC_V2,

 

BASIC_SET_V2 - is triggered when a 

change of output state of relay occurs.

 

Отзывы: