QUBINO ZMNHCD1 Скачать руководство пользователя страница 2

 

 

 

Byte DEC):   

 

default value 10 = 10% 

 

0 - reporting disabled 

 

1 - 100 = 1% - 100% Reporting enabled. Power report 

is send (push) only when actual power (in Watts) in 

real time changes for more than set percentage 

comparing to previous actual power in Watts, step is 

1%. 

NOTE: if power changed is less than 1W, the report is not 

send (pushed), independent of percentage set. 

Parameter no. 42 –  Power reporting in Watts by time 

interval for Q1 or Q2 

Set value means time interval (0 –  32767) in  seconds, 

when power report is send.  Available configuration 

parameters (data type is 2 Byte DEC):   

 

default value 0 = reporting disabled 

 

0 - reporting disabled 

 

1  -  32767 = 1 second -  32767  seconds. Reporting 

enabled, power report is send with time interval set by 

entered value.   

Parameter no. 71 – Operating modes 

This parameter defines selection between two available 

operating modes. Available configuration parameters (data 

type is 1 Byte DEC):   

 

default value 0 

 

0 - Shutter mode 

 

1 - venetian mode (up/down and slate rotation) 

NOTE1:  After parameter change, first exclude module 

(without setting parameters to default value) then wait at 

least 30s and then re include the module! 

Parameter no. 72 – Slats tilting full turn time 

This parameter defines the time necessary for slats to 

make full turn (180 degrees).  Available configuration 

parameters (data type is 2 Byte DEC):   

 

default value 150 = 1,5 seconds 

 

0 - tilting time disabled 

 

1 - 32767 = 0,01seconds - 327,67 seconds 

NOTE:  If time set is too high, this will result that after full 

turn, Shutter will start move up or down, for time remaining. 

Parameter no. 73 – Slats position 

This parameter defines slats position after up/down 

movement through Z-Wave  or push-buttons.  Available 

configuration parameters (data type is 1 Byte DEC):   

 

default value 1   

 

0 - Slats return to previously set position only in case 

of Z-Wave control (not valid for limit switch positions). 

 

1  -  Slats return to previously set position in case of 

Z-Wave  control, push-button operation or when the 

lower limit switch is reached. 

Parameter no. 74 – Motor moving up/down time 

This parameter defines Shutter  motor moving time of 

complete opening or complete closing.   Available 

configuration parameters (data type is 2 Byte DEC):   

 

default value 0 

 

0 – moving time disabled (working with limit   

switches) 

 

1 - 32767 = 0,1seconds - 3276,7seconds 

After that time motor is stopped (relay goes to off 

state) 

NOTE: Important is that the reference position to manually 

set moving time is always Shutter lower position! 

Set parameter 74 to 0 and move the Shutter  (using 

up/down push buttons or  main controller  UI) to the lowest 

desired position. On this Shutter position, set parameter 74 

to time for complete opening or complete closing. At this 

point Shutter can be moved up (open) for set time, but can't 

be moved down because  this position is already set as 

lower Shutter position. 

To change Shutter  lower position below already set 

(manual recalibration), parameter 74 must be set to 0 and 

repeat the procedure described above. 

In case Shutter  has limit switches, but anyhow you would 

like to limit opening/closing position by time, you can still do 

it. In case you put time that is longer that opening/closing 

real time limited by limit switches, Shutter will stop at limit 

switch, but the module relay will switch off after define time, 

not by Shutter limit switch. Take in consideration that in this 

condition, the positioning with slider through UI will not 

show correct Shutter position. 

Parameter no. 76 - Motor operation detection 

Power threshold to be interpreted when motor reach the 

limit switch.  Available configuration parameters (data type 

is 1 Byte DEC):   

 

default value 30 = 30W 

 

0 - 127 = 1-127 W. The value 0 means reaching a limit 

switch will not be detected. 

Parameter no. 78 - Forced Shutter calibration 

By modifying the parameters setting from 0 to 1 a Shutter 

enters the calibration mode. Available configuration 

parameters (data type is 1 Byte DEC):   

 

default value 0 

 

1 - Start calibration process (when calibration process 

is finished,  completing full cycle -  up, down and up, 

set the parameter 78 (Forced Shutter calibration) 

value back to 0. 

Parameter no. 85 – Power consumption max delay time 

This parameter defines the max time before motor power 

consumption  is read after one of the relays is switched 

ON.   If there is no power consumption during this max time 

(motor not connected, damaged or requires higher time to 

start, motor in end position) the relay will switch OFF. Time 

is defined by entering it manually.  Available configuration 

parameters (data type is 1 Byte DEC):   

 

default value 30 = 3s   

 

0 = time is set automatically 

 

3 - 50 = 0,3seconds - 5seconds (100ms resolution) 

Parameter no. 90 –  Time delay for next motor 

movement 

This parameter defines the minimum time delay between 

next motor movement (minimum time between switching 

motor off and on again). Available configuration parameters 

(data type is 1 Byte DEC):   

 

default value 5 = 500ms 

 

1 - 30 = 0,1seconds - 3seconds (100ms resolution) 

Parameter no. 110 –  Temperature sensor offset 

settings 

Set value is added or subtracted to actual measured value 

by sensor. Available configuration parameters (data type is 

2 Byte DEC): 

 

default value 32536 

 

32536 - offset is 0.0C 

 

From 1 to 100 -  value from 0.1 °C   to 10.0 °C is 

added to actual measured temperature.   

 

From 1001 to 1100 - value from -0.1 °C to -10.0 °C is 

subtracted to actual measured temperature. 

Parameter no. 120 - Temperature sensor reporting 

If digital temperature sensor is connected, module reports 

measured temperature on temperature change defined by 

this parameter.  Available configuration parameters (data 

type is 1 Byte DEC): 

 

default value 5 = 0,5°C   

 

0 - Reporting disabled 

 

1-127 = 0,1°C - 12,7°C, step is 0,1°C

 

Parameter No. 250 – Unsecure / Secure Inclusion 

Available configuration parameter (data type is 1 Byte 

Dec): 

 

default Value 0 

 

  Unsecure Inclusion 

 

  Secure Inclusion 

A Flush dimmer supports secure and unsecure inclusion. 

Even if the controller does not support security command 

classes, a dimmer could be included as unsecure and keep 

all the functionality.   

 
Technical Specifications 

Power supply 

110 - 230 VAC ±10% 

50/60Hz, (24-30 VDC) 

Rated load current of AC 

output (resistive load)* 

2 X 4A / 230VAC 

Output circuit power of AC 

output (resistive load) 

2 X 920W (230VAC) 

Power measurement 

accuracy 

P=0-200W, +/-2W 

P>200W, +/-3% 

Digital temperature sensor 

range (sensor must be 

ordered separately)

 

-50 ~ +125°C 

Operation temperature 

-10 ~ +40°C 

Distance 

up to 30 m indoors 

(depending on building 

materials) 

Dimensions (WxHxD) 

(package) 

41,8x36,8x16,9mm 

(79x52x22) 

Weight (Brutto with package)  28g (34g) 

Electricity consumption 

0,4W 

For installation in boxes 

Ø ≥ 60mm or 2M

,   

depth

≥ 60mm

 

Switching

 

Relay (2x) 

*In case of load other than resistive, pay attention to the 

value of cos φ and if necessary apply load lower than the 
rated load. Max current for cos φ=0,4

 is 2A at 250VAC. 

Supported loads: 

 

  Electric motor 

 

Z-Wave Supported Command Classes:   

COMMAND_CLASS_ZWAVEPLUS_INFO_V2, 

COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 

COMMAND_CLASS_POWERLEVEL_V1 

COMMAND_CLASS_SECURITY 

Securely Supported Command Classes: 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

COMMAND_CLASS_SWITCH_ALL_V1 

COMMAND_CLASS_SWITCH_BINARY_V1 

COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

COMMAND_CLASS_METER_V4 

COMMAND_CLASS_SENSOR_MULTILEVEl_V7 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_MULTI_CHANNEL_V4 

COMMAND_CLASS_ASSOCIATION_2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_CONFIGURATION_V1 

COMMAND_CLASS_MARK 

COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

Endpoint1:   
Device Class:   

BASIC_TYPE_ROUTING_SLAVE 
GENERIC_TYPE_SWITCH_MULTILEVEL 
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 
COMMAND_CLASS_SWITCH_ALL_V1 
COMMAND_CLASS_SWITCH_BINARY_V1 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
COMMAND_CLASS_METER_V4 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 
COMMAND_CLASS_MARK 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

Endpoint2:   
Device Class:   

BASIC_TYPE_ROUTING_SLAVE 
GENERIC_TYPE_SWITCH_MULTILEVEL 
SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_SWITCH_ALL 
COMMAND_CLASS_SWITCH_BINARY_V1 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 
COMMAND_CLASS_MARK 
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

Endpoint 3: 
Device Class: 

GENERIC_TYPE_SENSOR_MULTILEVEL 
SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

NOTE

:

 The above list is valid for the product with a 

temperature sensor connected to TS terminal at the time of 

inclusion. In case the sensor is not connected then the 

following command class and endpoint 3 are not 

supported: 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 

Endpoint 2 is supported by the module only when the 

parameter no. 71 is set to the value 1 and the module is 

excluded and re-included into the network.   

This product can be included and operated in any Z-Wave 

network with other Z-Wave certified devices from any other 

manufacturers. All constantly powered nodes in the same 

network will act as repeaters regardless of the vendor in 

order to increase reliability of the network. 

COMMAND_CLASS_BASIC: 

The module will be turned ON or OFF after receiving the 

BASIC_SET command. To be turned ON: [Command Class 

Basic , Basic Set, Basic Value = 0x01~0x63 in percentage; FF 

set to last value] 

To be turned OFF:[Command Class Basic , Basic Set, Basic 

Value = 0x00] 

This Security Enabled Z-Wave Plus product can be included and 

operated in any Z-Wave  network with other Z-Wave  certified 

devices from any other manufacturers. All constantly powered 

nodes in the same network will act as repeaters regardless of the 

vendor in order to increase reliability of the network. 

Security 

Enabled Z-Wave Controller must be used in order to fully utilize 

the product.

 

Important disclaimer

 

Z-Wave  wireless communication is inherently not always 

100% reliable, and as such, this product should not be used 

in situations in which life and/or valuables are solely 

dependent on its function.

 

Warning! 

Do not dispose of electrical appliances as unsorted 

municipal waste, use separate collection facilities.   

Contact your local government for information regarding 

the collection systems available. If electrical appliances are 

disposed of in landfills or dumps, hazardous substances 

can leak into the groundwater and get into the food chain, 

damaging your health and well-being. When replacing old 

appliances with new once, the retailer is legally obligated to 

take back your old appliance for disposal at least for free of 

charge. 

This user manual is subject to change and improvement 

without notice.

 

NOTE

: User manual is valid for module with SW version S6 

(SW version is part of P/N)! 

Example: P/N: ZMNHCD x Hx

S6

Px 

 

Qubino

 

Goap d.o.o. Nova Gorica 

Ulica Klementa Juga 007 

5250 Solkan 

Slovenia 

 

E-mail:  

[email protected]

   

Tel:       +386 5 335 95 00 

Web:     

www.qubino.com

     

 

Date: 29.06.2017   

Document: Qubino_Flush Shutter PLUS 

user

 

manual_V1.6_eng                                  