NOTE: The device is reporting following values:
kWh (import/export)
kvarh
kVAh
W, A, V, PF, kvar
NOTE: If measured active power (W) is below 5W -> the value is reported on time interval.
Parameter no. 45 – Reset Power counters
Values (size is 1 byte dec):
Default value 0
0 – no function
1 – reset counter 1 –kWh import
2 – reset counter 2 – kvarh
4 – reset counter 3 – kVAh
8 – reset counter 4 – kWh export
15 – reset ALL counters
Parameter no. 100 – Enable / Disable endpoints IR external relay and External relay
Enabling IR external relay and External relay or both of them, means that endpoint (IR external
relay) and endpoint (External relay) or both will be present on UI. Disabling them will result in
hiding endpoints according to Parameter set value. Note that hiding endpoint has no impact on
its functionality.
Values (size is 1 byte dec):
default value 0
0 - Endpoints IR external relay and External relay disabled
1 - Endpoints IR external relay disabled, External relay enabled
2- Endpoints IR external relay enabled, External relay disabled
3- Endpoints IR external relay and External relay enabled
NOTE1: After parameter change, first exclude device (without setting parameters to default
value) and then re include the device.