QUBINO Smart meter Скачать руководство пользователя страница 1

 

 

 

USER MANUAL 

 EN

.

         

     

 

 

 

QUBINO SMART METER 

 

 

The Qubino Smart Meter is an extremely versatile and powerful Z-Wave device for measuring 

energy in a single-phase electrical power network of up to 65A. 

 

Содержание Smart meter

Страница 1: ...USER MANUAL EN QUBINO SMART METER The Qubino Smart Meter is an extremely versatile and powerful Z Wave device for measuring energy in a single phase electrical power network of up to 65A...

Страница 2: ...make your life easier 11 3 Qubino Smart Meter Advantages and Highlights 12 3 1 Advantages 12 3 2 Highlights 15 4 Package Contents 16 5 Technical Terms for Switches 17 6 Compatibility with Z Wave Gate...

Страница 3: ...additional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We...

Страница 4: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...

Страница 5: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...

Страница 6: ...919 8 MHz ZMNHTD8 50 60 Hz 865 2 MHz ZMNHTD9 50 60 Hz 922 5 MHz ZMNHTDA 50 60 Hz 919 7 921 7 923 7 MHz ZMNHTDB 50 60 Hz 868 1 MHz ZMNHTDC 50 60 Hz 868 1 MHz ZMNHTDD 50 60 Hz 919 8 MHz ZMNHTDE 50 60 Hz...

Страница 7: ...mart Meter can be used in residential industrial and utility applications It measures energy directly in 2 wire networks by means of fast sampling of voltage and current signals It calculates energy p...

Страница 8: ...Ah Energy Reactive power accumulated kvarh Smart Meter supported functions Associations Z Wave Repeater Auto inclusion Optional functions Turn ON OFF device 1 Turn ON OFF device 2 Automatically turn O...

Страница 9: ...bino Smart Meter to measuring energy in a single phase electrical power network of up to 65A and remotely control devices via your smartphone 2 1 Installation examples for the Smart Meter used for mea...

Страница 10: ...el numbers IKA232 20 230V 030 046 833 000 BICOM432 40 WM1 30 074 038 Remotely control and measure the power consumption of one electrical device for example water heater with external relay BICOM432 4...

Страница 11: ...devices lights off after they exceed the set power consumption For example the heating will automatically turn off after it reaches the set power consumption value This function is independent of oth...

Страница 12: ...ion and the Qubino Smart Meter is a DIN rail mounted device so the installation is really simple The Qubino Smart Meter is the only single phase smart meter worldwide which allows connection of additi...

Страница 13: ...Energy Apparent power accumulated kVAh Energy Reactive power accumulated kvarh Qubino guarantees 100 device quality Such high quality can be delivered because every Qubino goes through rigorous quali...

Страница 14: ...The serial and part numbers of your device are given automatically every time you open an inquiry with our support team this instantly shares the relevant device information we need to provide the be...

Страница 15: ...evices of this kind DIN rail installation Saves and restores the last status after a power failure Supports auto inclusion mode for quick set up Can automatically turn devices on and off after a set p...

Страница 16: ...EN 16 4 Package Contents Smart Meter Device Installation Manual...

Страница 17: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...

Страница 18: ...2018 and it may not include the latest testing data Smart Meter U I W kWh PF kVarh kVah kVar Relay 1 Relay 2 Relay1 Relay2 Domoticz V3 5877 Fibaro HC Lite v 4 130 X Vera Edge v 1 7 2406 Zipato Z Wave...

Страница 19: ...to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Electrical installation must be protected by over current prote...

Страница 20: ...or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some voltage may remain in the...

Страница 21: ...EN 21 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Before Qubino installation...

Страница 22: ...EN 22 After Qubino installation For measuring energy of the house...

Страница 23: ...EN 23 For controlling one electrical device with BICOM432 40 WM1 BICOM is sold separately for more info please see Qubino catalogue Product ordering code model number 30 074 038...

Страница 24: ...EN 24 For controlling one electrical device with IKA232 20 230V IKA is sold separately for more info please see Qubino catalogue Product ordering code model number 030 046 833 000...

Страница 25: ...al devices with IKA232 20 230V and one with BICOM432 40 WM1 IKA and BICOM are sold separately for more info please see Qubino catalogue Product ordering codes model numbers IKA232 20 230V 030 046 833...

Страница 26: ...EN 26 Step 3 Turn ON the fuse Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...

Страница 27: ...EN 27 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Smart Meter...

Страница 28: ...the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part num...

Страница 29: ...utput 5 Output for External relay max 3W S Service button used to add or remove device from the Z Wave network LED1 Device status For detailed information please check the chapter LED SIGNALIZATION FO...

Страница 30: ...t W Power Active var Power Reactive PF Power Factor kWh Energy Active power accumulated Import kWh Energy Active power accumulated Export kVAh Energy Apparent power accumulated kvarh Energy Reactive p...

Страница 31: ...One controlled by built in optical IR communication port on the side second controlled by output on terminal 5 IKA and BICOM are sold separately for more info please see Qubino catalogue Product orde...

Страница 32: ...s to this relay is hidden and can be enabled by changing the value of the configuration parameter 100 IKA232 20 230VIKA232 20 is a bistable switch which can be controlled in contrast to the IR relay u...

Страница 33: ...Connect the device to the power supply 5 Auto inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enrol in your network NOTE For S2 inclus...

Страница 34: ...S service button between 0 2 and 6 seconds 5 The device will be removed from your network but custom configuration parameters will not be erased FACTORY RESET 1 Connect the device to the power supply...

Страница 35: ...l IR relay is turned OFF LED is 0 5s OFF 0 5s ON IR communication error b External TRIAC relay enabled only LED is ON External IR relay is turned ON LED is OFF External IR relay is turned OFF c Both T...

Страница 36: ...EN 36 12 Associations Association Groups Group 1 Lifeline group reserved for communication with the primary gateway hub 1 node allowed...

Страница 37: ...h function selection Values size is 1 byte dec Default value 4 0 disabled 2 IR external relay control mono stable push button 3 IR external relay control bi stable switch 4 External relay control mono...

Страница 38: ...mand Values size is 2 byte dec Default value 0 0 59 Auto OFF disabled 60 32535 60 seconds 32535 seconds Parameter no 12 Automatic turning on External IR relay output after set time When External IR re...

Страница 39: ...mand Values size is 2 byte dec Default value 0 0 59 Auto OFF disabled 60 32535 60 seconds 32535 seconds Parameter no 14 Automatic turning on External relay output after set time When External IR relay...

Страница 40: ...is not send pushed NOTE when power is changed for more than percent value in this parameter the device is reporting also A if the value has changed V if the value has changed Power Factor if the valu...

Страница 41: ...ternal relay and External relay or both of them means that endpoint IR external relay and endpoint External relay or both will be present on UI Disabling them will result in hiding endpoints according...

Страница 42: ...f Set value means Maximum Power Consumption 0 15000 in watts W when relays are turned off according to parameters no 111 and 112 Values size is 2 byte dec default value 0 0 no function 1 15000 1 W 150...

Страница 43: ...ize is 1 byte dec default value 0 0 switch between the 2 relays power off relay 1 first after power on if power consumption is still over power off relay 2 1 always power off relay 1 IR external relay...

Страница 44: ...e connection single phase 1b Reference current Iref 5 A Maximum current Imax 65 A Minimum current Imin 0 25 A Starting current 20 mA Voltage Un 230 V 20 Power consumption at Un 2W Nominal frequency fn...

Страница 45: ...ing standards for indoor active energy Meters Temperature and climatic condition according to EN 62052 11 Dust water protection IP20 Operating temperature 15 55 C Storage temperature 40 70 C Enclosure...

Страница 46: ...OMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_CONF...

Страница 47: ...AND CLASSES COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_SECURITY_V1 COMMAND_CLASS_SECURITY_2_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_...

Страница 48: ...ON Command Class Basic Basic Set Basic Value 0x01 0x63 FF To be turned OFF Command Class Basic Basic Set Basic Value 0x00 BASIC SET GET on root device is mapped to basic set get of both endpoints COMM...

Страница 49: ...node requesting to join the S2 Access Control Class or the S2 Authenticated Class will obfuscate its Public Key by setting the bytes 1 2 to zeros 0x00 before transferring its key via RF A joining nod...

Страница 50: ...er is legally obligated to take back your old appliance for disposal free of charge 19 Regulations Legal Notice This user manual is subject to change and improvement without notice GOAP d o o Nova Gor...

Страница 51: ...s part of P N Example P N ZMNHTDxHxS7Px Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 29 3 2018 V 2 3 DON T MIS...

Отзывы: