background image

2

3

1. Connect the communications cable

 from the tap to the water heater.

WARNING: 

To not 

damage

 the water heater, 

especially for the first time turning the water 

heater on, you must run the water through 

the boiling function five times. (for the touch 

tap this is the 3 step sequence). 

When the water heater lights turn green, the 

system has the correct temperature and 

ready to use. 

4. Power up the water heater. A red light will 

show on the top right of the water heater.

5. Look for the 

SmartTap™

 buttons on the 

panel to light up.

6. Look for the 

TouchTap™

 panel four (4) 

quadrants to illuminate and then turn off.

1. Activate the boiling flow at the tap control 

within 2 minutes of powering up.

• If you have the Smart-

Tap™ this will be the red il-

luminated button.

• If you have the TouchTap™, this has a sim-

ple three (3) touch sequence - top left quad-

rant, then the bottom left, then top left again. 

Please refer to the TouchTap™ installation 

manual. 

2. Allow water to run for approx. Thirty (30) 

seconds, then deactivate.

3. Wait for 1 minute and repeat, allowing wa-

ter to flow for 30 seconds. Repeat this pro-

cess three (3) times.

1.

 Note:

 It is essential to understand the inlet 

solenoid that controls the flow of water into 

the chiller carbonator from the water heater 

unit. The inlet solenoid has to be open when 

we do this commissioning sequence because 

running the pump dry will lead to failure. 

To 

activate the solenoid, activate the sparkling 

water. 

4. When the green light on the water heater 

unit appears and the red light goes out, the 

water heater has reached its temperature. 

Your water heater unit is now commissioned 

and ready for use.

Note: 

 If you do not see the panels light up

check the communication cable is connected 
properly. 

Note:

 The 

SmartTap™

 required 6 activations 

every minute. Repeat every minute for 5 min-
utes.

NOTE:

 that you will see water running through 

the venturiT™ to drain during this process. 

This unique device enables the water heater 

to vent safely to drain during expansion and 

also removes any water left in the spout af-

ter use.

2. Turn on the cold water supply to the ¼” in-

let on the front right side of the water heater.

3. Connect the power cable provided for the 

water heater. 

(Note: that this is rated 110 Volts/ 15Amp)

SECTION A:

Commissioning sequence for 

Quatreau Touch™ and SmartTap™ 

Boilers (553-B) 

SECTION B:

Water Heater Venting Procedure

SECTION C:

Commissioning the Chiller 

Carbonator 

CS20

DO NOT TURN ON POWER TO CHILLER 

UNTIL INSTRUCTED TO DO SO. 

COMMISSIONING 

WATER HEATER & CHILLER