1. Connect the communications cable
from the tap to the water heater.
WARNING:
To not
damage
the water heater,
especially for the first time turning the water
heater on, you must run the water through
the boiling function five times. (for the touch
tap this is the 3 step sequence).
When the water heater lights turn green, the
system has the correct temperature and
ready to use.
4. Power up the water heater. A red light will
show on the top right of the water heater.
5. Look for the
SmartTap™
buttons on the
panel to light up.
6. Look for the
TouchTap™
panel four (4)
quadrants to illuminate and then turn off.
1. Activate the boiling flow at the tap control
within 2 minutes of powering up.
• If you have the Smart-
Tap™ this will be the red il-
luminated button.
• If you have the TouchTap™, this has a sim-
ple three (3) touch sequence - top left quad-
rant, then the bottom left, then top left again.
Please refer to the TouchTap™ installation
manual.
2. Allow water to run for approx. Thirty (30)
seconds, then deactivate.
3. Wait for 1 minute and repeat, allowing wa-
ter to flow for 30 seconds. Repeat this pro-
cess three (3) times.
1.
Note:
It is essential to understand the inlet
solenoid that controls the flow of water into
the chiller carbonator from the water heater
unit. The inlet solenoid has to be open when
we do this commissioning sequence because
running the pump dry will lead to failure.
To
activate the solenoid, activate the sparkling
water.
4. When the green light on the water heater
unit appears and the red light goes out, the
water heater has reached its temperature.
Your water heater unit is now commissioned
and ready for use.
Note:
If you do not see the panels light up
check the communication cable is connected
properly.
Note:
The
SmartTap™
required 6 activations
every minute. Repeat every minute for 5 min-
utes.
NOTE:
that you will see water running through
the venturiT™ to drain during this process.
This unique device enables the water heater
to vent safely to drain during expansion and
also removes any water left in the spout af-
ter use.
2. Turn on the cold water supply to the ¼” in-
let on the front right side of the water heater.
3. Connect the power cable provided for the
water heater.
(Note: that this is rated 110 Volts/ 15Amp)
SECTION A:
Commissioning sequence for
Quatreau Touch™ and SmartTap™
Boilers (553-B)
SECTION B:
Water Heater Venting Procedure
SECTION C:
Commissioning the Chiller
Carbonator
CS20
DO NOT TURN ON POWER TO CHILLER
UNTIL INSTRUCTED TO DO SO.
COMMISSIONING
WATER HEATER & CHILLER