Ethernet Interface – Heavy-Duty package
Interface:
Ethernet 10Base-T
Connector:
Deutsch DTM-06-12SSA
Data Rates:
10 Mb/sec
Pin Assignments:
Pin
No.
Name
Description
1 TXTP+
T
2
RXTP+
3 NC
No
Connect
4
NC
No Connect
5
ON/IGN
Device power OBN. Active High (internal
pull-down).
Default ON
Pulling signal LOW shuts off the internal
power supply.
6
VBAT
Battery Power Input
7 GND
Ground
8
/F_RESET
Factory RESET. Active LOW (internal
pull-up).
Default OFF
Pulling signal low as power is applied will
RESET device settings to factory default
values.
9 NC
No
Connect
10
NC
No Connect
11 RXTP-
Receive-
12
TXTP-
Transmit-