User Manual 

 

 

 

SPEC 

MODEL 

SSI006UK 

SSI007UK 

SSI008UK 

SSI009UK 

SSI010UK 

SSI011UK 

IN

P

U

T

 

VOLTAGE 

10.8- 

15.5Vdc 

21.6-31Vdc 

10.8- 

15.5Vdc 

21.6-31Vdc 

10.8-15.5Vdc 

21.6-31Vdc 

EFFICIENCY 

Over 80% Efficiency 

POWER TYPE 

Open & Seal Lead Acid Battery, Regulated DC Alternator 

O

U

T

P

U

T

 

CONTINUOUS 

POWER 

1000W 

1000W 

1500W 

1500W 

2500W 

2500W 

SURGE 

POWER 

200% of Continuous Power for 2 sec to help starting up 

AC VOLTAGE 

230Vac ± 10% 50Hz 

SIGNAL WAVE 

FORM 

Modified Sine Wave 

USB 

5Vdc, 1.0A 

 

 

PROTECTIONS 

2 Phases Low Battery Protection (warning and critical shutdown), 

Input Over Power Protection, 

Overload Protection, 

Over Heat Protection, 

Short Circuit Protection 

DIMENSION (mm) 

26x15x7 

26x15x7 

30.5x22x9 

30.5x22x9 

37.5x22x9 

37.5x22x9 

WEIGHT (kg) 

1.87 

1.87 

3.55 

3.55 

5.88 

5.88 

AMBIENT WORK 

TEMPERATURE 

-15°C – 45°C 

STORAGE 

TEMPERATURE 

-40°C – 85°C 

HUMIDITY 

20% - 90% non-condensing 

Содержание SSI000

Страница 1: ...ny damaged caused by misusage of the product WARNING Contain high voltage and high current Do not open or attempt to repair yourself SSI000 001 002 003 004 005 006 007 008 009 010 011 12 and 24V Modif...

Страница 2: ...s Unlike pure sine wave inverters modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment For inductive load such as fluorescent light acoustic equipment a...

Страница 3: ...inner temperature less than 30 C the fan will not operate At load between 40 60 the fan will operate at 40 of its maximum speed At load between 60 80 the fan will operate at 60 of its maximum speed A...

Страница 4: ...cessories other than the ones provided may cause damage Mercury will not take any responsible for damage caused by use of third party accessories For cable cross section requirement for different mode...

Страница 5: ...the start up load is normally twice as much as the rated continuous power of the appliance In some equipment the start up load can be as high as 8 times of its continuous power especially on inductiv...

Страница 6: ...onstantly Do not pull on cable when unplugging from the inverter always grip firmly on the plug To avoid shock hazard always ensure inverter and DC power supply if apply are switched off before insert...

Страница 7: ...ash Low input power protection warning the input power is below 10 8V 0 2V for 12V input inverter and 21 6V 0 4V for 24V input inverter This indicates the power bank is running low or DC power supply...

Страница 8: ...on 24V input inverter 1 Check battery level if it is low please recharge before continuing use 2 On the battery cables used check the cross section area of the conductor is no thinner than recommended...

Страница 9: ...months must be shown for warranty to be valid Any unit that has been misused altered or accidentally damaged will not be covered by warranty Mercury will not be responsible for any damage cause as res...

Страница 10: ...SURGE POWER 200 of Continuous Power for 2 sec to help starting up AC VOLTAGE 230Vac 10 50Hz SIGNAL WAVE FORM Modified Sine Wave USB 5Vdc 1 0A PROTECTIONS 2 Phases Low Battery Protection warning and c...

Страница 11: ...1 pair 4mm2 20A 4 50Ah SSI006UK 12V 1 pair 10mm2 35A 4 160Ah SSI007UK 24V 1 pair 6mm2 20A 4 80Ah SSI008UK 12V 2 pairs 10mm2 35A 6 250Ah SSI009UK 24V 2 pairs 6mm2 20A 6 125Ah SSI010UK 12V 2 pairs 16mm2...