E5000 Manual 30 April 2020 

Page 2 of 6 

 

Quartzlock

 

Precision Frequency Engineering  

E5000

  

Safety Considerations

 

General 

This  product  and  related  documentation  must  be  reviewed  for  familiarisation  before  operation.  If 
the equipment is used in a manner not specified by the manufacturer, the protection provided by 
the instrument may be impaired. 

Before Applying Power 

Verify that the product is set to match the available line voltage and the correct fuse is installed. 

Before Cleaning 

Disconnect the product from operating power before cleaning. 

WARNING  

Bodily injury or death may result from failure to heed a warning. Do not proceed beyond a warning 
until the indicated conditions are fully understood and met. 

 

CAUTION 

Damage to equipment, or incorrect measurement data, may result from failure to heed a caution. 
Do not proceed beyond a caution until the indicated conditions are fully understood and met. 

This equipment must be earthed 

An  uninterruptible  safety  earth  ground  must  be  maintained  from  the  mains  power  source  to  the 
product’s ground circuitry. 

WARNING 

When measuring power line signals, be extremely careful and use a step down isolation transformer 
whose output is compatible with the input measurement capabilities of this product. The product’s 
front and rear panels are typically at earth ground. Thus, never try to measure AC power line signals 
without an isolation transformer. 

 

WARNING 

Instructions  for  adjustments  when  covers  are  removed  and  for  servicing  are  for  use  by  service-
trained  personnel  only.  To  avoid  dangerous  electrical  shock,  do  not  perform  such  adjustments  or 
servicing unless qualified to do so. 

 

WARNING 

Any  interruption  of  the  protective  grounding  conductor  (inside  or  outside  the  instrument)  or 
disconnecting of the protective earth terminal will cause a potential shock hazard that could result 
in personal injury. Grounding one conductor of a two conductor out-let is not sufficient protection. 

Whenever  it  is  likely  that  the  protection  has  been  impaired,  the  instrument  must  be  made 
inoperative and be secured against any unintended operation. 

If  the  instrument  is  to  be  energised  via  an  autotransformer  (for  voltage  reduction)  make  sure  the 
common terminal is connected to the earthed pole terminal (neutral) of the power source. 

Instructions for adjustments while the covers are  removed and for servicing are for use by service-
trained  personnel  only.  To  avoid  dangerous  electrical  shock,  do  not  perform  such  adjustments  or 
servicing unless qualified to do so. 

For continued protections against fire, replace the line fuse(s) with fuses of the same current rating 
and  type  (for  example,  normal  blow time  delay).  Do not use repaired  fuses  of short-circuited  fuse 
holders. 
 
 
 
 

Содержание E5000

Страница 1: ...E5000 Manual 30 April 2020 Page 0 of 6 Quartzlock Precision Frequency Engineering E5000 MODEL E5000 Low Noise Distribution Amplifier USER S HANDBOOK...

Страница 2: ...nts Safety Considerations 2 Voltage Frequency and Power Characteristics 3 Environmental Conditions 3 Replaceable Fusing Characteristics 3 Cleaning Instructions 3 Operating Procedure 4 Front panel LED...

Страница 3: ...e product s front and rear panels are typically at earth ground Thus never try to measure AC power line signals without an isolation transformer WARNING Instructions for adjustments when covers are re...

Страница 4: ...using Characteristics 800mA time lag HBC Cleaning Instructions To ensure long and trouble operation keep the unit free from dust and use care with liquids around the unit Be careful not to spill liqui...

Страница 5: ...ut One input is provided This has input impedance of 50 Ohms The input level can be between 5dBm and 13 dBm Outputs The E5000 configurable up to 24 outputs These have source impedance of 50 Ohms and w...

Страница 6: ...y Response a 1MHz to 20MHz 1 0dB b 1MHz to 110MHz 3 0dB 6 Harmonics at rated output 10MHz source harmonics less than 60dBc a Second Harmonic 50dBc b Third Harmonic 35dBc 7 Isolation a Output to Output...

Страница 7: ...put 24 32 output Option 12 2 inputs 12 24 outputs Option 13 3 inputs 12 24 32 outputs Option 18 Extended warranty to 3 years Option 51 Rack Mount 19 1U Option 52 Rack Mount 19 2U Option 53 Rack Mount...

Страница 8: ...Frequency Engineering E5000 Quartzlock 179 Junction Road Burgess Hill RH15 0JW UK Tel 44 0 1444 232967 E mail sales quartzlock com Web www quartzlock com Registered in England 708818 VAT Registration...

Отзывы: