Page 5
Frequency 50 - 60Hz
Power characteristics 600mA Max
Output Voltage 15V DC 1.2A
1.2.2 Unit Power Requirements
Input Voltage
12Vdc – 18Vdc
Input Current
1.7A max
1.3 Environmental Conditions
1.3.1 Temperature
Operating (ambient)
-20
o
C to +50
o
C
Charging
0
o
C to +45
o
C
Storage
-20
o
C to +40
o
C
1.3.2 Magnetic Field
Sensitivity
≤2x10
-11
/ Gauss
Atmospheric Pressure
-60m to 4000m
<1x10
-13
/ mbar
1.4 Cleaning Instructions
To ensure long and trouble free operation, keep the unit free from dust and
use care with liquids around the unit.
Be careful not to spill liquids onto the unit. If the unit does get wet, turn the
power off immediately and let the unit dry completely before turning it on
again.
Never spray cleaner directly onto the unit or let liquid run into any part of it.