Quartzlock A5-32 Скачать руководство пользователя страница 5

 

 

Model A5-32 Operation And Service Manual

 

A5-32 Manual 29 April 2002 

Page 5 of 10

 

 

Distribution Amplifier A5-12 

Operating Procedure 

Introduction 

The Quartzlock model A5-12 is a linear distribution amplifier designed for standard frequency 
distribution between 1 MHz and 100 MHz. The circuit is based on a number of balanced linear 
amplifiers with high reverse isolation and low phase noise. Twelve of these amplifiers are used to 
drive the twelve 50

Ω

 outputs. They are called the output amplifiers in the following description. A 

modified version of the output amplifier with a gain control, called the input amplifier, drives a 
twelve way passive power splitter. This divides the signal with an insertion loss of about 12 dB, and 
provides isolation of about 20 dB. The output amplifiers each have an output signal monitor circuit, 
which is used as part of the output fail monitoring. 

Input 

One input is provided. This has input impedance of 50

Ω

. The input level should be between 0 and 

+13 dBm. 

Outputs 

Up to twelve outputs are provided. These have source impedance of 50

Ω

, and will provide 13 dBm 

nominal into a 50

Ω

 load. Maximum output is up to 16 dBm. 

Содержание A5-32

Страница 1: ...l 29 April 2002 Page 1 of 10 MODEL A5 32 32 Way Distribution Amplifier USER S HANDBOOK Quartzlock UK Ltd Gothic Plymouth Road Totnes Devon TQ9 5LH England Tel 44 0 1803 862062 Fax 44 0 1803 867962 Web...

Страница 2: ...requency and Power Characteristics 4 Environmental Conditions 4 Replaceable Fusing Characteristics 4 Cleaning Instructions 4 Distribution Amplifier A5 12 5 Operating Procedure 5 Circuit Descriptions 6...

Страница 3: ...transformer whose output is compatible with the input measurement capabilities of this product The product s front and rear panels are typically at earth ground Thus never try to measure AC power lin...

Страница 4: ...t 10 C to 55 C 65 to 65 op Storage 40 C to 85 C Magnetic Field Sensitivity 2x10 11 Gauss Atmospheric Pressure 60m to 4000m 1x10 13 mbar Replaceable Fusing Characteristics 800mA time lag HBC Cleaning I...

Страница 5: ...lled the output amplifiers in the following description A modified version of the output amplifier with a gain control called the input amplifier drives a twelve way passive power splitter This divide...

Страница 6: ...of 13 dBm the second harmonic distortion is less than 60 dBc due to the differential design Third harmonic distortion is less than 40 dBc The bandwidth is 1 dB from 2 MHz to 100 MHz The gain falls by...

Страница 7: ...analyser to measure the harmonic distortion and verify against the specifications Repeat for other outputs if desired Take care that the spectrum analyser is not generating harmonics so as to affect...

Страница 8: ...ser to any input and search for discrete spurii Calculate their level in dBc related to the 13 dBm nominal output Measure the wideband noise using a preamplifier if necessary to improve the spectrum a...

Страница 9: ...at nominal output 10 MHz Source harmonics less than 60dBc a Second harmonic 50dBc b Third harmonic 40dBc 7 Isolation a Output to output 90dB adjacent outputs at 10 MHz 70dB adjacent outputs at 100 MHz...

Страница 10: ...Model A5 32 Operation And Service Manual A5 32 Manual 29 April 2002 Page 10 of 10 Appendix...

Отзывы: