 Distribution Amplifier A5-24 

Operating Procedure 

Introduction 

The Quartzlock model A5-24 is a linear distribution amplifier designed for standard frequency 
distribution between 1 MHz and 100 MHz. The circuit is based on a number of balanced linear 
amplifiers with high reverse isolation and low phase noise. Twelve of these amplifiers are used to 
drive the twelve 50

Ω

 outputs. They are called the output amplifiers in the following description. A 

modified version of the output amplifier with a gain control, called the input amplifier, drives a 
twelve way passive power splitter. This divides the signal with an insertion loss of about 12 dB, and 
provides isolation of about 20 dB. The output amplifiers each have an output signal monitor circuit, 
which is used as part of the output fail monitoring. 

Input 

One input is provided. This has input impedance of 50

Ω

. The input level should be between 0 and 

+13 dBm. 

Outputs 

Twenty-four outputs are provided. These have source impedance of 50

Ω

, and will provide 13 dBm 

nominal into a 50

Ω

 load. Maximum output is up to 16 dBm. 

Power Supply

 

This unit operates from its own mains driven power supply, set at the factory to operate from 240V 
ac. An internal switch on the power supply enables operation from 120V ac if required. The mains 
fuse may need increasing in rating at 120V mains supply.

Содержание A5-24

Страница 1: ...l 20 March 2002 Page 1 of 10 MODEL A5 24 24 Way Distribution Amplifier USER S HANDBOOK Quartzlock UK Ltd Gothic Plymouth Road Totnes Devon TQ9 5LH England Tel 44 0 1803 862062 Fax 44 0 1803 867962 Web...

Страница 2: ...3 Voltage Frequency and Power Characteristics 4 Environmental Conditions 4 Replaceable Fusing Characteristics 4 Cleaning Instructions 4 Distribution Amplifier A5 24 5 Operating Procedure 5 Output Ampl...

Страница 3: ...transformer whose output is compatible with the input measurement capabilities of this product The product s front and rear panels are typically at earth ground Thus never try to measure AC power lin...

Страница 4: ...t 10 C to 55 C 65 to 65 op Storage 40 C to 85 C Magnetic Field Sensitivity 2x10 11 Gauss Atmospheric Pressure 60m to 4000m 1x10 13 mbar Replaceable Fusing Characteristics 800mA time lag HBC Cleaning I...

Страница 5: ...nput amplifier drives a twelve way passive power splitter This divides the signal with an insertion loss of about 12 dB and provides isolation of about 20 dB The output amplifiers each have an output...

Страница 6: ...1 MHz A tuned version of the output amplifier is possible by replacing T2 by a tuned transformer T4 and by adding C21 This reduces harmonic distortion further and also reduces integrated wide band noi...

Страница 7: ...o the spectrum analyser and or tracking generator cables to avoid common mode cross talk The output to output isolation is defined as the tracking generator level minus the level measured by the spect...

Страница 8: ...ing Up The only user adjustment required is to set the output levels To do this proceed as follows 1 Remove the lid 2 Connect desired input between 0 and 13 dBm 3 Connect a spectrum analyser oscillosc...

Страница 9: ...cs at nominal output 10 MHz Source harmonics less than 60dBc a Second harmonic 50dBc b Third harmonic 40dBc 7 Isolation a Output to output 90dB adjacent outputs at 10 MHz 70dB adjacent outputs at 100...

Страница 10: ...Model A5 24 Operation And Service Manual A5 24 Manual 20 March 2002 Page 10 of 10 Appendix...

Отзывы: