2800 & 2900 Series PLC Drivers

Page 17

DM2829_PLC Revision 2

Yaskawa MP930 Port 2

Quartech Part Number: 2164-10

MP930 Port 2

2800/2900 

9 Pin Male D-Type

15 Pin Female D-Type

RXD

3 <

)))))))))))))))))))))))

< 2

TXD

TXD

2 <

)))))))))))))))))))))))

< 3

RXD

SC

7 <

)))))))))))))))))))))))

< 7

SC

RTS

4 <

))),

             

+)))))

< 4

RTS

CTS

5 <

)))-

             

.)))))

< 5

CTS

DSR

6 <

))),

DTR

9 <

)))-

Yaskawa, MP930 Memobus Interface

The MP930 interface uses RS-232 signal levels and is intended for point to point communication, i.e., only a single
peripheral device may be connected to the MP930 port. The OIT will be capable of reading and writing data to all MW
and Ml address locations. The 2800 and 2900 communicate using the T-Series Computer Link ASCII protocol.

ScreenMaker 2000 Port setup:

Node address: 1 through 247
Baud rate: 9600 bps or 19200 bps
Command Word Address: (MW Type), one word
Screen Trigger Address: (MW Type),  two contiguous words

Byte format:

 8 data bits, 1 stop bit, even parity

The following schematic shows the cable connections required between the OIT and the MP930 port 2 . This cable
is available from Quartech in a standard length of ten feet. Cables up to fifty feet in length may be ordered.

NOTES:

The OIT can directly address locations MW00000 through MW32767, and ML00000 through ML32767. Address type
MB is accessed using the Bit Status Field or Bit Status function key designation. 

Up to four OITs can be connected to a single MP930 port using the Quartech Model 8517 Multiplexer.

Содержание 2800

Страница 1: ... as to the acceptability of each application and the use of the unit Under no circumstances will QUARTECH CORPORATION be responsible or liable for any damage including indirect or consequential losses resulting from the use misuse or application of the unit The text illustrations charts and examples included in this document are intended solely to help explain applications of the product Due to th...

Страница 2: ...n necessary for connecting either unit to a particular brand or model of Programmable Controller PLC Communication Drivers Page Allen Bradley PLC 5 DF1 2 Allen Bradley SLC500 DF1 3 Allen Bradley SLC500 DH485 4 Allen Bradley PLC 2 6 Fuji Electric N Series 7 GE Fanuc Series Ninety 8 Idec Micro 3 Series 9 Mitsubishi FX Series 11 Modicon MODBUS 12 Omron Host Link 13 Toshiba EX100 Protocol 14 Toshiba T...

Страница 3: ...he Command Word Element 1 is Screen Trigger one Element 2 is Screen Trigger two Byte format 8 data bits 1 stop bit no parity PLC 5 processor configuration Use Allen Bradley programming software to configure the PLC 5 processor as shown below The baud rate may be 9600bps as long as it matches the OIT setting The following schematic shows the cable connections required between the OIT and the PLC 5 ...

Страница 4: ...ned and must be an Integer type file Element 0 is the Command Word Element 1 is Screen Trigger one Element 2 is Screen Trigger two Byte format 8 data bits 1 stop bit no parity SLC500 processor configuration Use Allen Bradley programming software to configure the SLC500 processor as shown below The baud rate may be 9600bps as long as it matches the OIT setting The following schematic shows the cabl...

Страница 5: ... Node 0 31 OIT Max poll address A single Dialogue File address is assigned and must be an Integer type file Element 0 is the Command Word Element 1 is Screen Trigger one Element 2 is Screen Trigger two Byte format 8 data bits 1 stop bit even parity When connecting multiple devices on the network an Allen Bradley 1747 AIC Isolated Link Coupler should be used between the SLC500 processor and the phy...

Страница 6: ...er the network A total of 32 devices may share the DH485 Data Link network When only a few devices are sharing the network the soliciting time can become considerable To reduce unnecessary soliciting a maximum poll address may be assigned in the OIT and most other devices designed for use on the network The OIT and other devices utilizing this feature will send a solicit successor message only to ...

Страница 7: ...rminating resistors are required for a network regardless of the number of devices in the network One terminating resister is connected at each end of the network The OIT includes a terminating resistor that is switched into to the circuit by closing a DIP switch accessible through the cover Refer to the Hardware Manual for the particular OIT to identify which DIP switch is assigned If the OIT is ...

Страница 8: ...nded for point to point communications i e only a single peripheral device may be connected to the PLC port ScreenMaker 2000 Port setup Command Word Address Internal Bits M Type one word Screen Trigger Address Data Register D Type two contiguous words Communication format 8 data bits 1 stop bit odd parity 19200bps The following schematic shows the cable connections required between the OIT and the...

Страница 9: ...uses RS 485 signal levels Although a single master multiple slave network is possible the OIT does not support it ScreenMaker 2000 Port setup Baud rate 9600 bps or 19200 bps Command Word Address Internal Relay M Type one word Screen Trigger Address Data Register R Type two contiguous words Byte format 8 data bits 1 stop bit odd parity The following schematic shows the cable connections required be...

Страница 10: ...both point to point communications and network communications are available ScreenMaker 2000 Port setup PLC Type Micro 3 RS 485 Micro 3C RS 232 Data Link RS 485 Host PLC node address 0 through 1F hexadecimal Command Word Address Internal Relay M Type one word Screen Trigger Address Data Register D Type two contiguous words Communication format 7 data bits 1 stop bit even parity 9600 bps The follow...

Страница 11: ... trunk line are not recommended and may degrade or prevent network operation As the trunk line length increases two factors become increasingly important These factors are line resistance and line capacitance In most applications the use of line terminating resistors will improve or allow satisfactory performance Two terminating resistors are required for a network regardless of the number of devi...

Страница 12: ...S PWE 5 CTS 4 Drain Wire 1 DCC 7 17 5VDC 24 The FX Series interface uses signal levels is intended point to point communications i e only a single peripheral device may be connected to the FX port Command Word Address Internal Coil M Type one word Screen Trigger Address Data Register D Type two contiguous words 7 data bits 1 stop bit even parity 9600bps The following shows the connections required...

Страница 13: ... point communications i e only a single peripheral device may be connected to the MODBUS port ScreenMaker 2000 Port setup Baud rate 9600 bps or 19200 bps PLC Address 1 through 247 Interface type RS 232 or RS 485 Command Word Address Output Coil 0xxxx one word Screen Trigger Address Output Register 4xxxx two contiguous words Byte format 8 data bits 1 stop bit even parity RTU protocol The following ...

Страница 14: ...onnected to the port A single master multiple slave ScreenMaker 2000 Port setup Interface type RS 232 or RS 422 Baud rate 9600 bps or 19200 bps Command Word Address Internal Bits HR Type one word Byte format 7 data bits 2 stop bit even parity following schematic the cable required between OIT and LK201 Host port This cable is available from Quartech in a standard length of ten feet Cables up to fi...

Страница 15: ...al device may be connected to the port This driver is compatible with Toshiba models EX100 EX250 EX500 M20 and M40 It is also compatible with the Cutler Hammer D500 processor ScreenMaker 2000 Port setup Command Word Address Internal Relays RW Type one word Screen Trigger Address Data Register D Type two contiguous words Interface type Custom 4800 bps 8 data bits 1 stop bit even parity The followin...

Страница 16: ...nfigured using the RS 485 One PLC be as the meaning the Word and Triggers are in it The OIT will be capable reading and data to PLCs on network The and 2900 using the Computer ScreenMaker 2000 Port setup Interface type RS 232 or RS 485 Baud rate 9600 bps or 19200 bps Byte format 8 data bits 1 stop bit odd or no parity Screen Trigger Address Data Register D Type two contiguous words Th This is avai...

Страница 17: ...T Series Computer Link ASCII protocol ScreenMaker 2000 Port setup Node address 1 through 247 Baud rate 9600 bps or 19200 bps Command Word Address MW Type one word Screen Trigger Address MW Type two contiguous words Byte format 8 data bits 1 stop bit even parity The following schematic shows the cable connections required between the OIT and the MP930 port 2 This cable is available from Quartech in...

Отзывы: