Quark-Elec QK-R022 Скачать руководство пользователя страница 4

Quark-Elec Application Note

http://www.quark-elec.com

4 of 5

2015

V1.0

4.2 Learn communication code

1. Press the ‘SET’ button on QK-R022, the LED light will turn on. Then press ‘up’ button on the remote
controller, the LED will quickly blink for few seconds. Once the LED keeps light on, the transmitter
code has been stored in QK-R022 and ‘Up’ button has been paired with QK-R022.
2. Repeat the step1 for ‘Down’ button to pair with QK-R022.
3. Repeat the step1 for ‘Stop’ button to pair with QK-R022.
4. Press ‘Stop’ button again, the LED will blink and then turn off.

By now, QK-R022 is ready for control by the remote controller.

5 R

EMOTE CONTROLLER TYPES

Two remote controller types are available for this item: Wall-hung type and portable type. Please see
the following picture for details.

Figure 4 Remote controller types

6 O

PERATING

S

PECIFICATIONS

Item

Specification

Frequency bands

Quad-band: 433MHz

433Mhz modulation mode

ASK (AM)

Typical transmitting range

35 meters(indoor); 200 meters (open air)

Operating temperature

-25°C to +80°C

Storage temperature

-40°C to +85°C

DC supply

12.0V(+/-10%) or 24.0((+/-5%))

Average supply current (typical
quiescent)

10mA

Rated current on relay

30A12VDC or 30A24VDC

Rated voltage on relay

12 to 24VDC

Portable type

Wall-hung type

Отзывы: