Quark-elec Manual
3 of 7
2022
V1.00
converters are required. It is also recommended for marine electronics engineers or technicians, who
require direct access to a vessel’s NMEA 2000 network data, for testing or investigative purposes.
Please refer to the Conversion List chapter for details of supported (and non-supported)
conversions.
If you need a NMEA 0183 to NMEA 2000 small size converter, please choose
2. Mounting
The AS00 is aimed at the commercial, leisure and fishing boat markets.
It is not waterproof so should be mounted in a dry place such as behind the instrument panel on a flat
surface.
Figure 2: AS00 Dimension in mm
3. Connecting
Disconnect all power sources before connecting your equipment!
3.1. Connecting to the NMEA 2000 network
The AS00 is pre-fitted with a five-core screened cable for the NMEA 2000 connection, fitted with a male
micro-fit connector. Simply connect the cable to the NMEA 2000 network backbone or using a T-piece
connector.
Figure 3: Pin NMEA 2000 male micro-fit connection
The main communication channel of an NMEA 2000 network is an NMEA 2000 backbone to which
NMEA 2000 devices are connected. The NMEA 2000 backbone must be powered from a stable 12V DC