Replacing a Tape Drive with a Filler Plate

5

Bring the tape drive online, if it is not online already. 

a

From the Operator panel, select 

Actions > Tape Drive 

and select

 

Change Mode

b

Select the tape drive you want to bring online and press 

Modify

c

Use the 

Up

 button to change the mode to 

Online

, then press 

Apply

.

The tape drive LED turns green. 

6

Verify the installation by reviewing the Library Configuration report:

a

From the Web client 

Reports > Library Configuration

b

Make sure that the new drive is online, in the correct partition, and has 
the control path status that you want. You may need to refresh your 
Internet browser.

7

Verify that the host computer and backup applications can see the new tape 

drive configuration correctly. 

8

If any empty slots remain, install a filler plate in the empty slot (see 

Replacing a Tape Drive with a Filler Plate

 on page 4). 

Caution:

Filler plates are required to maintain proper library cooling. Do 

not run the library with uncovered slots.

9

Run the tape drive diagnostic test on the newly installed tape drive to be 
sure it is functioning correctly: 

a

Install a scratch tape in the top I/E station slot.

b

If manual cartridge assignment is enabled, assign the scratch tape to 
the System partition.

c

From the Operator panel, select 

Tools > Diagnostics

.

d

Continue through the next few screens to run the tape drive test on the 
replaced tape drive. 

If a problem is found during testing, you receive a diagnostic ticket. See the 

Scalar i40 and Scalar i80 User’s Guide

 for more information about the tape 

drive test. 

Replacing a Tape Drive with a Filler Plate

The filler plate is half-height in size. If you remove a full-height tape drive, you 
must install two filler plates to cover the opening.

1

The tape drive filler plate has no “top” or “bottom” orientation – it can go in 
either way (see 

Figure 3

 on page 5). 

2

Slide the filler plate into the slot, and tighten the thumbscrews. 