Q9VOIP SERIES MANUAL

file:///C|/PACH-CO.COM-2022-B/online_manual/q9000voip_manual.htm[4/27/2022 8:57:08 AM]

The product comes with two years Limited Warranty, see above for more detail

Description

The Quantum Q9000VOIP Series is multi tenant telephone entry system.

Analog dial tone is supplied by AATA2

Capacity 900 tenants, 2000 cards or keyfobs and 900 access codes.

Specification

Input power

: 12VAC 40VA (12VAC supplied) or 12VDC 3.0A

Minimal Current consumption

: 750-100mA

DIMENSION: 

9-13/16"(H) x 11-13/16"(W) x 3-1/2"(D)

1x16 Liquid Crystal Display (LCD)
Built-in 26 Bit Wiegand Card Reader
RS-485 for Satellite system (up to eight satellite)
Two on-board relays
Two Auxiliary inputs
Two Door Sensors
Operating environment 10ºF-140ºF
Relative Humidity 0%-95% non-condensing
Double 3/4" knocks-out on the back and bottom panel

Features

Web Based programming
Event recording
Automatic Enrollment
900 tenants, 2000 cards or keyfobs, 900 access codes
20 programmable time zones, 10 programmable auto-unlock schedules and 20 holiday schedules
10 programmable temporary cards and access codes for limited use
10 programmable unlock hold cards and access codes

Accessories and Replacement parts

Visit our web site www.pach-co.com

For missing part(s) call at (888) 678-7224, Monday-Friday 7:30 AM -4:00 PM Pacific Standard Time.

CHAPTER 2
Installation and Wiring Diagram

Follow the wiring diagram carefully. Improper installation will void the warranty. 

Please call technical support in case you have any difficulties during the installation

.

Click the selection below for different applications
 
 

Содержание Q9000VOIP Series

Страница 1: ...vent Recording Function Code 16 Auto Unlock Schedule AUS Function Code 17 Time Zone TMZ Function Code 18 Holiday Zone HLD Function Code 23 Lock out Count Function Code 24 Alarm Function Code 25 Keypad...

Страница 2: ...ed in shipment or failures which result from accidents misuse abuse neglect bug infestation mishandling misapplication alteration faulty installation setup adjustment misadjustment of consumer control...

Страница 3: ...nsors Operating environment 10 F 140 F Relative Humidity 0 95 non condensing Double 3 4 knocks out on the back and bottom panel Features Web Based programming Event recording Automatic Enrollment 900...

Страница 4: ...such exit switch postal lock etc 8 DOORS1 DOORS2 GND Door Sensor connect to door swicth to monitor door opening and closing 9 RS 485 Slave units connection up to 8 slave units 10 26 BIT Wiegand Input...

Страница 5: ...se incorrect letter or number exit programming CALL ENTER EXCEPT PROGRAM CHAPTER 4 Programming Log in to Programming Mode 1 Press 0 and simultaneously then release the welcome screen will stop scrolli...

Страница 6: ...2951 then press Return to step 3 to enter another tenant directory Function Code 02 Edit Existing Tenant Directory 1 Log in to programming 2 Enter 02 then the display will show 3 Enter tenant director...

Страница 7: ...is selected the system can t make calls 1 Log in to programming 2 Enter 05 then 3 Enter 0 disable default pr 1 enable then press Function Code 06 Add New Access Code An access code is a keyless entry...

Страница 8: ...3 to program another access code 1 add additional time zone then press and return to step 6 exit programming Function Code 07 Delete Access Code 1 Log in to programming 2 Enter 07 then 3 Enter code t...

Страница 9: ...p to 16 characters then press 5 Enter door 1 or 2 or 3 for both then press 6 Enter time zone 1 3 then press 7 Enter 00 24 hours 20 see function code 17 then press 8 Enter satellite system ID 0 7 enter...

Страница 10: ...in to programming 2 Enter 12 then 3 Enter 1 to clear all keyfobs or cards press or to cancel Function Code 13 Set Time 1 Log in to programming 2 Enter 13 then 3 Enter HH in military time MM minute the...

Страница 11: ...mming 2 Enter 15 then Enter 1 then to clear event buffer or to cancel deletion Function Code 16 Auto Unlock Schedule AUS Unlocking and locking the door as program automatically If the open time is 06...

Страница 12: ...mming 2 Enter 17 then 3 Enter 01 20 00 24 hours access automatically then press 4 Enter 0 Delete the existing time zone then press or 1 add new time zone then press 5 Enter start time in military then...

Страница 13: ...call 1 Log in to programming 2 Enter 19 then 3 Enter 2 3 or 4 digit then press Function Code 20 AUXIN1 AUXIN1 is used for input device such as postal lock infrared sensor exit button etc AUXIN1 is as...

Страница 14: ...d as specified on the Lock out Count 1 Log in to programming 2 Enter 23 then 3 Enter 1 9 default 3 then press Function Code 24 Alarm The system has a warning alarm if invalid code or card has been ent...

Страница 15: ...er 27 then 3 Enter 10 240 seconds then press Function Code 28 Unlock Relay 1 Time The amount of time for relay 1 to trigger 1 Log in to programming 2 Enter 28 then 3 Enter 01 99 second then press Func...

Страница 16: ...press 8 Enter time zone set 1 3 then press 9 Enter 00 24 hours 20 see function code 17 then press 10 Enter Sat id 0 7 then press enter 0 if no satellite connected to the QR5 11 Enter 0 no more additio...

Страница 17: ...er 0 if no satellite connected to the QR5 11 Enter 0 no more additional time zone then press and return to step 3 to program another temporary code 1 add additional time zone then press and return to...

Страница 18: ...en press and return to step 3 to program another temporary code 1 add additional time zone then press and return to step 8 exit programming Function code 36 Special Card The card can be use to unlock...

Страница 19: ...is connected to fax machine alarm panel or any answering device Disable this function 1 Log in to programming 2 Enter 38 then 3 Press 0 disable auto answer 1 9 answer in 1 9 rings then press Function...

Страница 20: ...Press 1 9 9 is default setting then press Function Code 42 Relay 2 Mode Relay 2 can be set to four different mode 1 door control 2 trigger simultaneously as relay 1 3 alarm mode see function code 24 4...

Страница 21: ...Zone Relay The system s relay can be disabled during certain time but the system is still in full operation Maximum 10 disable time zones 1 Log in to programming 2 Enter 44 then 3 Enter 0 9 then pres...

Страница 22: ...PBX then 9 is necessary before dialing an outside line If this function is enabled then the system can only be dialing an outside line it cannot dial the extension 1 Log in to programming 2 Enter 48...

Страница 23: ...creen It consists of three segments and 16 characters for each segment 1 Log in to programming 2 Enter 51 then 3 1st segment enter the characters then press see Chapter 3 for keypad layout 4 2nd segme...

Страница 24: ...card reader Other manufacturers card will not work Swipe the card or keyfob as shown below The card reader antenna is mounted behind the black square window 5 5 Extending Talk Time The talk time timer...

Страница 25: ...Q9VOIP SERIES MANUAL file C PACH CO COM 2022 B online_manual q9000voip_manual htm 4 27 2022 8 57 08 AM...

Отзывы: