Battery Condition Meter

The battery condition meter consists of a 7-segment display on the LCD. As the battery voltage drops, 

the number of lights reduces from top to bottom. When the battery capacity drops to 10% or below, the 

bottom segment will flash. 

 

„

Bottom Segment Flashing: The battery charge is low; charge the batteries as soon as possible.

 

„

Upward Ripple of Segments with Charging Plug: The controller is in charging mode.

 

„

All or No Segments Flashing Quickly (Code): The controller has detected a fault; refer to the Error 

Code table.

Right/Left Turn Indicator Buttons (for Optional Equipment)

The right/left turn indicator buttons toggle either the left or right turn indicators. Press once to turn on and 

press again to turn off. You can also turn off the selected turn indicator by pressing the opposite indicator 

button or the hazard button.

Light Button (for Optional Equipment)

The light button turns the headlights/taillights on and off independent of other indicators.

Hazard Button (for Optional Equipment)

The hazard key activates both turn indicators at the same time. You can cancel this only by pressing the 

hazard button again.

Power Accessory Indicators (for Optional Equipment)

Indicates the selected power accessory. This is only for optional accessories.

NOTE: If your power chair is equipped with power accessories such as a power elevating seat or 

power elevating leg rests, you can operate them through the keypad buttons, joystick, mono jack 

switch, and attendant control. Refer to “Actuator Adjustment.”

Controller Connector

This connects the NE+ controller to the power module located on the power base.

Off-Board Charger/Programming Socket

You may use an off-board charger to charge the power chair batteries through the 5-pin socket located 

on the front of the NE+ controller. If you use an off-board charger, the charger current should not exceed 

8 amps. Contact your Pride/Quantum Rehab Provider for more information.

WARNING! Only chargers with Neutrik NC3MX plugs should be connected to the off-board charger/

programming socket. See your Pride/Quantum Rehab Provider for more information.

NOTE: The socket may also be used for reprogramming the NE+ controller. Contact your Pride/

Quantum Rehab Provider for more information.

Speed Adjustment/Profile Select 

To select a speed setting or drive profile:

1.  Press the on/off button to power on the controller.

2.  Press the drive profile decrease or drive profile increase button until you reach the desired speed/

profile setting.

NOTE: Drive profiles are set by your Pride/Quantum Rehab Provider. Contact your Pride/Quantum 

Rehab Provider to change a drive profile or change speed settings.

Содержание NE PLUS

Страница 1: ...Basic Operation Instructions ...

Страница 2: ...Identification Key Copyright 2016 INFMANU3765 Rev D October 2016 1 2 3 6 5 4 7 8 9 10 ...

Страница 3: ...10 Joystick Actuator Mode 1 Button Actuator Mode 2 Button Charger Port Profile Increase Button On Off Button Profile Decrease Button Controller Horn Button LCD Screen Mode Actuator and Power Switch Input Identification Key ...

Страница 4: ...4 Identification Key 1 2 3 7 5 6 4 9 10 8 11 12 ...

Страница 5: ... 10 11 Joystick Profile Increase Button Left Turn Indicator Button Charger Port Right Turn Indicator Button On Off Button Profile Decrease Button Controller Horn Button Hazard Button Light Button LCD Screen Mode Actuator and Power Switch Input ...

Страница 6: ...6 Identification Key 1 3 2 4 5 6 7 1 2 3 4 5 6 7 Attendant Control Mode Button Mode LED Actuator Indicators Battery Condition Meter On Off Button Joystick On Off and Mode Jacks ...

Страница 7: ...s a white symbol on a blue dot with a white border PROHIBITED These actions are prohibited These actions should not be performed at any time or in any circumstances Performing a prohibited action can cause personal injury and or equipment damage On the product this icon is represented as a black symbol with a red circle and a red slash NOTE These instructions are compiled from the latest specifica...

Страница 8: ...ttons for Optional Equipment 12 Light Button for Optional Equipment 12 Hazard Button for Optional Equipment 12 Power Accessory Indicators for Optional Equipment 12 Controller Connector 12 Off Board Charger Programming Socket 12 Speed Adjustment Profile Select 12 Actuator Adjustment 13 Attendant Control Joystick 14 Lock Mode 14 Sleep Mode 14 Thermal Rollback 14 NE Error Codes 15 Care and Maintenanc...

Страница 9: ...ry important for you to read and understand them completely Avoid exposure to rain snow ice salt or standing water whenever possible Maintain and store in a clean and dry condition Disposal and recycling Contact your Pride Quantum Rehab Provider for information on proper disposal and recycling of your Pride product and its packaging EMI RFI This product has been tested and passed at an immunity le...

Страница 10: ...r Follow all of the procedures and heed the warnings as explained in your power chair owner s manual Operating the NE Controller The NE controller is used to operate your power chair and all of its components The NE controller consists of Joystick Keypad Off board charger programming socket Controller connector Power module Joystick The joystick controls the direction and speed of your power chair...

Страница 11: ...here is a problem the warning icon will light and the turn indicator will flash at twice its normal rate 1 2 3 4 5 6 7 11 10 12 13 8 9 1 2 3 4 5 6 7 11 10 12 13 8 9 Identification Key 1 Charging Indicator 2 Lights Indicator 3 Battery Condition Meter 4 Lock Out 5 Actuator Error Indicator 6 Motor Brake Fault Indicator 7 Drive Profile Speed Indicator 8 Fault Indicator 9 Warning Indicator 10 Left Turn...

Страница 12: ...cessory This is only for optional accessories NOTE If your power chair is equipped with power accessories such as a power elevating seat or power elevating leg rests you can operate them through the keypad buttons joystick mono jack switch and attendant control Refer to Actuator Adjustment Controller Connector This connects the NE controller to the power module located on the power base Off Board ...

Страница 13: ...the on off button to power on the controller 2 Press either the profile decrease or increase button until you reach actuator mode 3 Push the joystick to the right or left to cycle through the available actuators The actuator indicators will display which actuator is activated 4 When the desired actuator is selected give a forward command to the joystick to lower the actuator or give a reverse comm...

Страница 14: ...e on the screen See NE Error Codes To unlock the controller 1 Press the on off key to turn on the controller The battery condition meter and a key will be displayed on the screen 2 Move the joystick to the full forward position until the controller beeps 3 Move the joystick to the full reverse position until the controller beeps 4 Release the joystick The controller is now unlocked Sleep Mode The ...

Страница 15: ...nd possible solutions If you receive one of these error codes follow the recommended solution If the problem persists or you receive any other error code or experience any other problem with your power chair contact your Pride Quantum Rehab Provider If the fault does not reset after performing the solution contact your Pride Quantum Rehab Provider Icon Display Diagnosis Solution Power Section Faul...

Страница 16: ... the batteries Battery Charging Inhibit Joystick powered on Unplug charger when charging is complete Battery Charging Inhibit Joystick powered off Unplug charger when charging is complete Idle Mode Cycle power If it continues contact your Pride Quantum Rehab Provider Attendant Control Fault Check Attendant Control connections and wiring NE Controller is locked out Unlock controller See Lock Mode i...

Страница 17: ...isposal instructions Temperature Some parts of your power chair are susceptible to extreme changes in temperature Always keep your power chair between the temperature of 18 F 8 C and 122 F 50 C Warranty Refer to your power chair owner s manual for specific information on controller warranty ...

Страница 18: ...18 Notes ...

Страница 19: ......

Страница 20: ...alia 20 24 Apollo Drive Hallam Victoria 3803 www quantumrehab com au New Zealand 38 Lansford Crescent Avondale Auckland New Zealand 1007 www pridemobility co nz Italy Via del Progresso ang Via del Lavoro Loc Prato della Corte 00065 Fiano Romano RM www quantumrehab italia it B V Castricummer Werf 26 1901 RW Castricum The Netherlands www quantumrehab eu www quantumrehab com ...

Отзывы: