Chapter 2: Introduction
Specifications
22
Quantum LTO-9 HH SAS User’s Guide
Power specifications
Other specifications
Environmental
specifications
Derate maximum dry-bulb temperature 1°C/300 m above 900 m (1.8°F/
1,000 feet above 3,000 feet).
Derate maximum recommended dry-bulb temperature 1°C/300 m above
1,800 m (1.8°F/1,000 feet above 6,000 feet).
Power Measurements
Drive
AC line current
100 to 240 Vac
Line frequency
50 to 60 Hz, auto-ranging
Line current at 100 Vac
0.48 A
Line current at 240 Vac
0.20 A
Specification
Measurement
Maximum altitude for operating and storage 3048 m (10,000 ft)
Maximum altitude for shipping
12192 m (40,000 ft)
Environmental Factor
Measurement
Recommended
Allowed
Shipping
Temperature
15 to 25°C
(59 to 77°F)
15 to 35°C
(59 to 95°F)
-40 to 60°C
(-40 to 140°F)
Relative humidity (non-
condensing)
20 to 50%
20 to 80%
10 to 90%
Maximum temperature
rate of change
5°C per hour
5°C per hour
N/A
Dew Point
Temperature
22°C (72°F)
22°C (72°F)
N/A
Airflow (Internal Drive)
3 cfm (.085 m
3
/min)