INSTALLATION and WIRING (CONTINUED)

4

5

Housing attachment to mounting plate:

Make certain all wires and connectors are 
routed to avoid interference with other 
components. Align latch openings on 
underside of housing with latch buttons
on mounting plate. Firmly push housing 
straight onto mounting plate, making 
certain all four latches are fully engaged, 
and the housing is closely aligned to the 
mounting surface.

FINAL ASSEMBLY

Battery Connection

Note: some details may vary

Connect the polarized battery plug to 
the charger board.  Make certain that 
the battery cable is routed to avoid 
interference with the AC input 
connector or other components.

Federal Communications 
Commission (FCC) Requirements:

This device complies with Part 15 of 
the FCC Rules. This device may not 
cause harmful interference.

battery connector

Battery

Lamp

Lamp

Status Indicator LED

Remote test Option
(standard with SDRT)

Test Switch

CAUTION: 

CAP UNUSED LEADS

WIRING DIAGRAM

Battery Type

Total Load

NiCd

2.4W

LiFePO4 (LTP)

4.8W

Input from branch circuit. See label 
on wire pair for voltage requirement.

DC output to the remote units. See label on wire 
pair for positive and negative polarity colors

Содержание ELM2LF

Страница 1: ...abrasions when removing from carton handling installing and maintaining this product WARNING The battery used in this device may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 70 C 158 F or incinerate Replace battery only as directed on the battery label and page 5 of these instructions Use of unauthorized battery voids warranty and UL listing of this product a...

Страница 2: ...mp Wires If no remote lamps are connected remote lamp leads and low voltage DC should be left capped and dressed in mounting plate as shown Taking care not to pinch wires or connectors dressed inside junction box secure mounting plate to junction box screws NOTE To ensure proper engagement of the mounting plate latches to the housing DO NOT OVER TIGHTEN THE SCREWS At upper center of the mounting p...

Страница 3: ...ect the polarized battery plug to the charger board Make certain that the battery cable is routed to avoid interference with the AC input connector or other components Federal Communications Commission FCC Requirements This device complies with Part 15 of the FCC Rules This device may not cause harmful interference battery connector Battery Lamp Lamp Status Indicator LED Remote test Option standar...

Страница 4: ...henever the total connected lamp load of the unit is changed or a lamp is replaced NOTE Manual load learning functions cannot be initiated if there is inadequate charge in the batteries If this is so wait until the unit indicates full battery charge solid green status indication before initiating the manual load learning function Clearing a failure indication After a failure condition has been cor...

Страница 5: ...essing the assembly toward the inside of the unit Gently bend the snap at each side of the bracket to release the lamp assembly Cut wires near lamp board and strip back 1 4in Connect stripped wires to the replacement lamp following the yellow blue polarity as marked Secure the new lamp assembly onto the lamp bracket and re assemble it into the housing routing the lamp wires to avoid damage by othe...

Страница 6: ...Part 912 00026 001 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 All Rights Reserved LIFE SAFETY SOLUTIONS TEL 800 334 8694 www lithonia com ...

Страница 7: ...ararlo ADVERTENCIA La batería utilizada en este dispositivo puede presentar un riesgo de incendio o quemadura química si no se utiliza correctamente No desmontar calentar a más de 70 C 158 F o incinerar Cambie la batería solo como se indica en la etiqueta de la batería y en la página 5 de estas instrucciones El uso de una batería no autorizada anula la garantía y la certificación UL de este produc...

Страница 8: ...os y colocados dentro de la placa de montaje como se muestra Teniendo cuidado de no presionar los cables o conductores organizados dentro de la caja de unión fije la placa de montaje a los tornillos de la caja de unión NOTA Para asegurar que los pestillos de la placa de montaje estén correctamente enganchados a la carcasa NO AJUSTE DEMASIADO LOS TORNILLOS En la parte superior del centro de la plac...

Страница 9: ...atería polarizado a la placa del cargador Asegúrese de verificar el recorrido del cable para evitar interferencias con el conector de entrada de CA o con otros componentes Requisitos de la Comisión Federal de Comunicaciones FCC Este dispositivo cumple con la Parte 15 de las reglas de la FCC Este dispositivo puede no ocasionar interferencias perjudiciales conector de la batería Batería Lámpara Lámp...

Страница 10: ... la lámpara conectada esté totalmente cargada o que una lámpara sea reemplazada NOTA Las funciones de aprendizaje de carga manuales no pueden iniciarse si las baterías no tienen carga suficiente Si esto es así espere hasta que la unidad indique que la batería ha sido totalmente cargada indicador de estado verde fijo antes de iniciar la función de aprendizaje de carga manual Aclaración de indicacio...

Страница 11: ... la lámpara y tira hacia atrás 1 4in Conecte los cables pelados a la lámpara de reemplazo siguiendo la polaridad amarilla azul marcada Sujete el nuevo el ensamblaje de la lámpara al soporte de la lámpara y vuelva a montarlo en la carcasa y direccione correctamente los cables de la lámpara para evitar daños de otros componentes Vuelva a ensamblar la unidad consulte también el paso 5 en la página 3 ...

Страница 12: ...N º de pieza 912 00026 001 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 Todos los derechos reservados SOLUCIONES DE SEGURIDAD PERSONAL TELÉFONO 800 334 8694 www lithonia com ...

Отзывы: