Installing the DXi6902 System in the Rack
29
DXi6902
Cabling the DXi6902
Follow these steps to cable the DXi6902:
1
Connect each Array module (RBOD) to the DXi6902 Node using the provided 2m
mini-SAS HD to mini-SAS cables (see
).
Note:
Mini-SAS plugs are rectangular
. Mini-SAS HD plugs are square
.
Caution:
The Mini-SAS HD plugs can be plugged in upside down. The cable will
appear to be inserted but is not. Verify the cable is seated by pulling
lightly on the cable. Verify the SAS link light is ON after powering on
the RBOD.
a
Connect port
RBOD1
(slot 5) on the Node to SAS port Ch 1 (Controller A) on
RBOD 1.
b
Connect port
RBOD1
(slot 6) on the Node to SAS port Ch 1 (Controller B) on
RBOD 1.
c
Connect port
RBOD2
(slot 5) on the Node to SAS port Ch 1 (Controller A) on
RBOD 2.
d
Connect port
RBOD2
(slot 6) on the Node to SAS port Ch 1 (Controller B) on
RBOD 2.