Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing Node Cooling Fans
98
Quantum DXi6902 User’s Guide
Figure 54 Removing and
Installing a Cooling Fan
Installing a Replacement Cooling Fan in the Node
To install the replacement cooling fan in the DXi6902 Node:
1
Align the plug at the base of the cooling fan with the connector on
the system board (see
).
2
Slide the cooling fan into the securing slots until the tabs lock into
place.
3
Close the Node cover (see
4
Turn on the system (see
Turning On and Shutting Down the System
5
In the remote management console, delete any administrative alerts
and close any service tickets.
Cooling fan assembly
Cooling fan connector
Fan release tab
Cooling fan