Chapter 3: FRU Removal and Replacement Procedures
Replacing an Array Module BBU
Quantum DXi6900 G2 Field Service Manual
170
Figure 116:
Removing and Installing an Array Module BBU
6. Unscrew the thumbscrew that secures the failed battery to the controller canister and remove the
battery.
Installing a Replacement Array Module BBU
To install the replacement Array module BBU:
1. Insert the new battery by sliding it towards the front of the controller canister (see
).
2. Tighten the thumbscrew that secures the new battery to the controller canister.
3. Reinstall the top cover on the controller canister.
4. Remove the controller air blocker from the controller slot.
5. Slide the replacement Array module controller into the empty bay until the controller snaps into place,
and push the handles into the closed position (see
Figure 115 on the previous page
).
6. Connect the SAS cables to the controller with the new BBU (see
DXi6900 G2 Cabling Diagrams on
):
7. Reset the BBU installation date: