Preparing for the Installation
3
DXi6700
Rack Space
Requirements
contains the rack requirements for the DXi6700 components.
Table 2 Rack Requirements
Environmental
Conditions
The installation site must have the following environmental conditions:
• Humidity: 20% to 80% (non-condensing)
• Temperature: 50° to 95°F (10° to 35°C)
• Altitude: –100 to 10,000 ft. (–30 to 3048 m)
These environmental conditions apply when the DXi6700 system is in operation.
Note:
For additional specifications, refer to the
Quantum DXi6700 User’s Guide
(PN 6-
67199) located on the documentation CD.
Preparing for the Installation
Before you begin the installation procedure in this section, make the following
preparations as described in this section:
•
•
Necessary Tools
Provide the following tools for unpacking and installing the DXi6700 system:
• #2 PHILLIPS screwdriver
• Notebook PC (for setting up initial system configuration)
Model 6700 Node
Expansion Module
Height
3U, 5.2 in. (13.2 cm)
2U, 3.5in (8.9 cm)
Width (side to side)
17.2 in. (43.7 cm)
17.2 in. (43.7 cm)
Depth (front to back)
25.5 in. (64.8 cm)
25.5 in. (64.8 cm)
Weight (stand alone)
72 lbs. (32.7 kg)
52 lbs. (23.6 kg)
Air Clearance
Open 4 in. (10.2 cm) behind unit for proper air flow