Appendix A: DXi4500 System Specifications
192
Quantum DXi6500 User’s Guide
Caution:
To safeguard backups in the event of a power outage,
Quantum recommends that you connect the DXi4500 to a
UPS (uninterruptable power supply).
Performance
Characteristics
lists the performance characteristics of the DXi4500 system.
DXi4510
Inrush
2.2A @ 100V
0.92A @ 240V
220W
Typical
2.0A @100V
0.83A @240V
200W
683 BTU/Hr
Maximum
7.5A @100V
4.0A @ 240V
750W
DXi4520
Inrush
3.0A @ 100V
1.3A @ 240V
300W
Typical
2.0A @100V
0.83A @240V
200W
683 BTU/Hr
Maximum
7.5A @100V
4.0A @ 240V
750W