DPM5500
Quick Start Guide
TABLE OF CONTENTS
Choosing a Location ..........................1
Rack Space Requirements...............1
Environmental Conditions .............1
Preparing for the Installation ...........2
Providing Necessary Tools ..............2
Taking ESD Precautions ..................2
Unpacking the DPM5500 ...................2
Installing the DPM5500 System ........2
Locating the Mounting Position ....3
Installing the DPM5500 Chassis .....3
Cabling the DPM5500 ........................5
DPM5500 Default Configuration.......6
DPM5500 Initial Configuration .........6
Microsoft® System Center Data
Protection Manager 2006................10
This quick start guides provides basic installation and configuration instructions for
the DPM5500 system. For more information on Microsoft DPM, see
http://
www.microsoft.com/windowsserversystem/dpm/default.mspx.
Choosing a Location
0
When choosing an installation site for the DPM5500 system, consider the
following requirements:
•
Rack Space Requirements
•
Environmental Conditions
Rack Space Requirements
0
Table 1
contains the rack requirements for the DPM5500.
Table 1 Rack Requirements
Environmental Conditions
0
The installation site must have the following environmental conditions:
•
Humidity: 20%-80% non-condensing
•
Temperature: 10°C-35°C (50°F-95°F)
•
Altitude: 0 to 10,000 feet (0 to 3048 meters)
These environmental conditions apply when the DPM5500 system is in operation.
DPM5500
Depth
25.4 in (64.5 cm)
Width
19 in (48.3 cm)
Height
8.75 in (22.2 cm), 5U
Weight
122 lbs (55.33 kg)
Air Clearance
Open 4.0 in (10.2 cm) behind unit for proper air
flow