Chapter 3 Media Changer Commands
Log Sense Command (4Dh)
Quantum ATL SuperLoader Software Interface Guide
59
Device Wellness
Page (33h)
3
The Device Wellness Page returns information about any check
conditions related to Sense Keys 4 and 9 logged by the media
changer. Up to 16 entries (parameter code 0000h to 000Fh) can be
contained in the page. Each entry records a hardware error (Sense
Key = 4) or a code update event (Sense Key = 9). Note that
parameter code 000h contains the oldest log information while
parameter 000Fh contains the most recent.
This page begins with a 4-byte header followed by the log
parameter blocks.
Figure 25 Device
Wellness Log Sense
Header
Table 23 Device
Wellness Log Sense
Header
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code (33h)
1
Reserved
2 - 3
(MSB)
Page Length
(LSB)
Field Name
Description
Page Code
The Page Code echoes the page code that was
specified in the LOG SENSE command descriptor
block.
Page Length
The Page Length field specifies the number of bytes
available and depends on the parameters requested.
Содержание ATL SuperLoader ATL
Страница 1: ...ATL SuperLoader DLT and ATL SuperLoader LTO Software Interface Guide 81 60220 01 A02...
Страница 18: ...Preface Document Conventions xviii Quantum ATL SuperLoader Software Interface Guide...
Страница 26: ...Chapter 1 Theory of Operation Automatic Drive Cleaning 8 Quantum ATL SuperLoader Software Interface Guide...
Страница 44: ...Chapter 2 Messages Supported SCSI Messages 26 Quantum ATL SuperLoader Software Interface Guide...
Страница 192: ...Chapter 3 Media Changer Commands Write Buffer Command 3Bh 174 Quantum ATL SuperLoader Software Interface Guide...
Страница 196: ...Index 178 Quantum ATL SuperLoader Software Interface Guide...