SCSI Commands
5-128
Quantum DLT 7000 Tape System
5.12
READ COMMAND (08h)
This command transfers one or more data blocks or bytes to the initiator
starting with the next block on the tape.
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (08h)
1
Logical Unit Number
Reserved
SILI
Fixed
2 - 4
(MSB)
Transfer Length
(LSB)
5
Unused
Reserved
Flag
Link
Figure 5–61 READ Command Descriptor Block - Data Format
Table 5–61 READ Command Descriptor Block - Field Descriptions
Field Name
Description
SILI
Suppress Incorrect Length Indicator. If the SILI bit is set to 1 and the Fixed bit is set to
1, the target terminates the command with CHECK CONDITION status, sense key set
to ILLEGAL REQUEST, and additional sense code of INVALID FIELD IN CDB.
If the SILI bit is 0 and the actual block length is different than the specified transfer
length, a CHECK CONDITION status is returned. Within the sense data, the Incorrect
Length Indicator (ILI) bit and Valid bit will be set to 1. The sense key field specifies
NO SENSE. The information bytes are set to the difference (residue) between the
requested transfer length and the actual block length., or, in Fixed Block mode, the
difference (residue) between the requested number of blocks and the actual number
of blocks read. No more than transfer length blocks are transferred to the initiator
and the tape is logically positioned after the block (EOM side).
Содержание 7000DLT Series
Страница 1: ...DLT 7000 Tape System Product Manual November 10 2003 81 60000 06...
Страница 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued...
Страница 6: ......
Страница 38: ...General Description and Specifications 1 14 Quantum DLT 7000 Tape System...
Страница 292: ...Appendix C Updating the Firmware C 6 Quantum DLT 7000 Tape System...
Страница 310: ...Index Index 6 Quantum DLT 7000 Tape Drive...
Страница 311: ......